* BASE * precise wall and z moved * PolyHoles * Arc-fitting * X-Y Compensation * Elephant foot + moved images * Update quality_settings_precision.md * Wall generator and more * Full Reorder * TPMS-D bases * Update strength_settings_infill.md * Image Fix + Infill desc calculator * Descriptions + image fix Co-Authored-By: Rodrigo <162915171+RF47@users.noreply.github.com> * Update cornering-calib.md * minor fixes * Wip updated * Missing fills * Update infill_desc_calculator.xlsx * Update infill_desc_calculator.xlsx * Update infill documentation and images Removed outdated 'iso' infill images and updated 'top' infill images with new versions. Added new images for adaptive cubic and 2D honeycomb infill patterns. Updated strength_settings_infill.md to revise infill strength values, descriptions, and remove references to deleted images. Introduced documentation for 2D honeycomb infill and made minor corrections and clarifications throughout. * Revise infill pattern documentation and add comparison table Updated strength_settings_infill.md to clarify infill density calculation, add a comprehensive comparison table of infill patterns, and standardize terminology for strength and print time. Expanded pattern descriptions to use qualitative strength ratings instead of numeric values. Updated infill_desc_calculator.xlsx to reflect these changes. * Indentation in code examples Adjusted the indentation of code blocks in the cornering calibration documentation for clarity and consistency with the rest of the document. * Update 3D Honeycomb infill strength ratings Adjusted the horizontal strength rating for 3D Honeycomb infill from 'Normal' to 'Normal-High' in the strength settings documentation and table. Updated the infill_desc_calculator.xlsx file to reflect these changes. * Formatting and fix in ERS documentation Updated headings to use consistent Markdown syntax, improved clarity in explanations, and reworded references for better readability. * Fix wall generator doc link and filename Updated the Home.md to reference the correct 'quality_settings_wall_generator' section and renamed the corresponding documentation file for consistency. --------- Co-authored-by: Rodrigo <162915171+RF47@users.noreply.github.com>
2.1 KiB
Max Volumetric speed
This is a test designed to calibrate the maximum volumetric speed of the specific filament. The generic or 3rd party filament types may not have the correct volumetric flow rate set in the filament. This test will help you to find the maximum volumetric speed of the filament.
You will be promted to enter the settings for the test: start volumetric speed, end volumentric speed, and step. It is recommended to use the default values (5mm³/s start, 20mm³/s end, with a step of 0.5), unless you already have an idea of the lower or upper limit for your filament. Select "OK", slice the plate, and send it to the printer.
Once printed, take note of where the layers begin to fail and where the quality begins to suffer. Pay attention to changes from matte to shiny as well.
Using calipers or a ruler, measure the height of the print at that point. Use the following calculation to determine the correct max flow value: start + (height-measured * step)
. For example in the photo below, and using the default setting values, the print quality began to suffer at 19mm measured, so the calculation would be: 5 + (19 * 0.5)
, or 13mm³/s
using the default values. Enter your number into the "Max volumetric speed" value in the filament settings.
You can also return to OrcaSlicer in the "Preview" tab, make sure the color scheme "flow" is selected. Scroll down to the layer height that you measured, and click on the toolhead slider. This will indicate the max flow level for your filmanet.
Note
You may also choose to conservatively reduce the flow by 5-10% to ensure print quality.
Tip
@ItsDeidara has made a html to help with the calculation. Check it out if those equations give you a headache here.