| OrcaSlicer use `M141/M191` command to control active chamber heater.  
 | |
| 
 | |
| If `Activate temperature control` is checked, OrcaSlicer will insert `M191` command at the beginning of the gcode(before `Machine G-code`).  
 | |
|   
 | |
| *Note: If the machine is equipped with an auxiliary fan, OrcaSlicer will automatically activate the fan during the heating period to help circulate air in the chamber.*  
 | |
| 
 | |
| 
 | |
| There are two chamber temperature variables available that we can use in `Machine G-code` to control the chamber temperature, if you prefer:  
 | |
| To access the chamber temperature set in the first filament, use:  
 | |
| `M191 S{chamber_temperature[0]}`  
 | |
| To use the overall chamber temperature, which is the highest chamber temperature set across all filaments, use:    
 | |
| `M191 S{overall_chamber_temperature}`
 | |
| 
 | |
| 
 | |
| --------------------------Klipper--------------------------  
 | |
| If you are using Klipper, you can define these macros to control the active chamber heater.  
 | |
| Bellow is a reference configuration for Klipper.   
 | |
| *Note: Don't forget to change the pin name/values to the actual values you are using in the configuration*
 | |
| 
 | |
| ```
 | |
| [heater_generic chamber_heater]
 | |
| heater_pin:PB10
 | |
| max_power:1.0
 | |
| # Orca note: here the temperature sensor should be the sensor you are using for chamber temperature, not the PTC sensor
 | |
| sensor_type:NTC 100K MGB18-104F39050L32
 | |
| sensor_pin:PA1
 | |
| control = pid
 | |
| pid_Kp = 63.418 
 | |
| pid_ki = 0.960
 | |
| pid_kd = 1244.716
 | |
| min_temp:0
 | |
| max_temp:70
 | |
| 
 | |
| [gcode_macro M141]
 | |
| gcode:
 | |
|     SET_HEATER_TEMPERATURE HEATER=chamber_heater TARGET={params.S|default(0)}
 | |
| 
 | |
| [gcode_macro M191]
 | |
| gcode:
 | |
|     {% set s = params.S|float %}
 | |
|     {% if s == 0 %}
 | |
|         # If target temperature is 0, do nothing
 | |
|         M117 Chamber heating cancelled
 | |
|     {% else %}
 | |
|         SET_HEATER_TEMPERATURE HEATER=chamber_heater TARGET={s}
 | |
|         # Orca: uncomment the following line if you want to use heat bed to assist chamber heating
 | |
|         # M140 S100
 | |
|         TEMPERATURE_WAIT SENSOR="heater_generic chamber_heater" MINIMUM={s-1} MAXIMUM={s+1}
 | |
|         M117 Chamber at target temperature
 | |
|     {% endif %}
 | |
| 
 | |
| ``` | 