OrcaSlicer/doc/calibration/input-shaping-calib.md
Ian Bassi 5ebb490a8d
Some checks failed
Build all / Build All (push) Waiting to run
Build all / Flatpak (push) Waiting to run
Publish docs to Wiki / Publish docs to Wiki (push) Has been cancelled
Wiki Update 11 - Strength (#10369)
* Create Patterns specific wiki

* Fix typos in installation instructions

Corrected the winget flag from --exact to -e and removed an extraneous backtick from the Mac xattr command in the README installation instructions.

* Improve README formatting and clarity

* Calibration Flow Ratio Yolo Archimedean cords

Co-Authored-By: MxBrnr <142743732+MxBrnr@users.noreply.github.com>

* redirection/tab.cpp section

* Missing Frequent

* remove auto-cooling

* remove thumbnails

* seam pointers

* walls

* infill

* Image standarization

* Fix broken internal links

* Add reference note to Arachne wall generator docs

* OrcaSlicer std

* PrusaSlicer std

* 2d-lateral xlsx

* vertical patterns

* Redirections fix

* Update speed_settings_overhang_speed.md

* Fix to action

* FlowRate

Co-Authored-By: MxBrnr <142743732+MxBrnr@users.noreply.github.com>

* Top Bottom Shells

* advanced strength

* Action fix

* Update How-to-wiki.md

* Home.md icons and reorganize sections

* Home Icons fix

* Update cornering-calib.md

* Update strength_settings_infill.md

* Update Auxiliary-fan.md

Co-Authored-By: Fisheye_3D <78997080+fisheye3d@users.noreply.github.com>

* Add warning about wiki maintenance status
2025-08-23 23:43:45 +08:00

7.2 KiB

Input Shaping

During high-speed movements, vibrations can cause a phenomenon called "ringing," where periodic ripples appear on the print surface. Input Shaping provides an effective solution by counteracting these vibrations, improving print quality and reducing wear on components without needing to significantly lower print speeds.

Klipper

Resonance Compensation

The Klipper Resonance Compensation is a set of Input Shaping modes that can be used to reduce ringing and improve print quality. Ussualy the recommended values modes are MZV or EI for Delta printers.

  1. Pre-requisites:
    1. In OrcaSlicer, set:
      1. Acceleration high enough to trigger ringing (e.g., 2000 mm/s²).
      2. Speed high enough to trigger ringing (e.g., 100 mm/s).

Note

These settings depend on your printer's motion ability and the filament's max volumetric speed. If you can't reach speeds that cause ringing, try increasing the filament's max volumetric speed (avoid materials below 10 mm³/s). 3. Jerk Klipper Square Corner Velocity to 5 or a high value (e.g., 20).

  1. In printer settigs:

    1. Set the Shaper Type to MZV or EI.
      SET_INPUT_SHAPER SHAPER_TYPE=MZV
      
    2. Disable Minimun Cruise Ratio with:
      SET_VELOCITY_LIMIT MINIMUM_CRUISE_RATIO=0
      
  2. Use an opaque, high-gloss filament to make the ringing more visible.

  3. Print the Input Shaping Frequency test with a range of frequencies.

    IS_freq_menu

    1. Measure the X and Y heights and read the frequency set at that point in OrcaSlicer.

    IS_damp_klipper_print_measure IS_freq_klipper_slicer_measure

    1. If not a clear result, you can measure a X and Y min and max acceptable heights and repeat the test with that min and max value.

Warning

There is a chance you will need to set higher than 60Hz frequencies. Some printers with very rigid frames and excellent mechanics may exhibit frequencies exceeding 100Hz.

  1. Print the Damping test setting your X and Y frequency to the value you found in the previous step.

    IS_damp_menu

    1. Measure the X and Y heights and read the damping set at that point in OrcaSlicer.

    IS_damp_klipper_print_measure IS_damp_klipper_slicer_measure

Important

Not all Resonance Compensation modes support damping.

  1. Restore your 3D Printer settings to avoid keep using high acceleration and jerk values.
  2. Save the settings
    1. You need to go to the printer settings and set the X and Y frequency and damp to the value you found in the previous step.

Marlin

ZV Input Shaping

ZV Input Shaping introduces an anti-vibration signal into the stepper motion for the X and Y axes. It works by splitting the step count into two halves: the first at half the frequency and the second as an "echo," delayed by half the ringing interval. This simple approach effectively reduces vibrations, improving print quality and allowing for higher speeds.

  1. Pre-requisites:
    1. In OrcaSlicer, set:
      1. Acceleration high enough to trigger ringing (e.g., 2000 mm/s²).
      2. Speed high enough to trigger ringing (e.g., 100 mm/s).

Note

These settings depend on your printer's motion ability and the filament's max volumetric speed. If you can't reach speeds that cause ringing, try increasing the filament's max volumetric speed (avoid materials below 10 mm³/s).

  3. Jerk
     1. If using [Classic Jerk](https://marlinfw.org/docs/configuration/configuration.html#jerk-) use a high value (e.g., 20).
     2. If using [Junction Deviation](https://marlinfw.org/docs/features/junction_deviation.html) (new Marlin default mode) this test will use 0.25 (high enough to most printers).
  1. Use an opaque, high-gloss filament to make the ringing more visible.

  2. Print the Input Shaping Frequency test with a range of frequencies.

    IS_freq_menu

    1. Measure the X and Y heights and read the frequency set at that point in OrcaSlicer.

    IS_freq_marlin_print_measure IS_freq_marlin_slicer_measure

    1. If not a clear result, you can measure a X and Y min and max acceptable heights and repeat the test with that min and max value.

Warning

There is a chance you will need to set higher than 60Hz frequencies. Some printers with very rigid frames and excellent mechanics may exhibit frequencies exceeding 100Hz.

  1. Print the Damping test setting your X and Y frequency to the value you found in the previous step.

    IS_damp_menu

    1. Measure the X and Y heights and read the damping set at that point in OrcaSlicer.

    IS_damp_marlin_print_measure IS_damp_marlin_slicer_measure

  2. Restore your 3D Printer settings to avoid keep using high acceleration and jerk values.

    1. Reboot your printer.
    2. Use the following G-code to restore your printer settings:
    M501
    
  3. Save the settings

    1. You need to go to the printer settings and set the X and Y frequency and damp to the value you found in the previous step.
    2. Use the following G-code to set the frequency:
    M593 X F#Xfrequency D#XDamping
    M593 Y F#Yfrequency D#YDamping
    M500
    

    Example

    M593 X F37.25 D0.16
    M593 Y F37.5 D0.06
    M500
    

Fixed-Time Motion

TODO: This calibration test is currently under development. See the Marlin documentation for more information.

Credits