In the initial PR for PP-71 I only cleaned up material_final_print_temperatures, but now the material_initial_print_temperatures are also coming into play, so I cleaned those as well. From research for PP-123 I know this is a safe change. Due to this cleanup the cool_min_temperature can now always follow the ultimaker default settings.
ultimaker.def.json is also cleaned and put in alphabetic order.
Ultimaker 2 and original are kept mostly as they were, since they are not tested. PP-42
We've removed a bunch of settings and transformed others. To allow profiles to be checked for these and edited if necessary, we now need to increment this version number.
Contributes to issue CURA-8466.
Since the setting version 18 is used in the arachne beta build, we decided to make the the setting version to 19 in the normal releases, so that we make sure that projects made in arachne beta won't use any version upgrade scripts if a user attempts to open them in 4.12.
CURA-8510
We now have version 18, where Flsun Super Racer has customised profiles.
Nothing changes in the built-in profiles. It only needs a change in the machine instances.
Contributes to issue CURA-8510.
We have a change now that requires a version upgrade. This triggers all profiles to update for the user, and we must update accordingly in the built-in profiles.
Contributes to issue CURA-7118.
Also convert the values for prime_tower_min_volume to make it behave similar to what the minimum volume used to be. This feature fixed a bug with the computation from volume to thickness. Now it's correct but we have to correct the old values to be still the same (approximately) as what used to be the end result.
Contributes to issue CURA-5457.
This reverts commit 9432252de4. It was assuming the wrong default speed_print value of 60. It's not always 60. We need to find a different solution or modify the script.
Reverts the fix for issue CURA-5342.
- Add a new field "variant" in "metadata" section for quality profiles.
"material" will only contain values such as "generic_abs", and
"variant" will contain values such as "0.25 mm", "AA 0.4", etc.
- Reformat "metadata" section to have the following order:
- setting_version
- type
- quality_type
- weight
- global_quality
- material
- variant
CURA-4451
- Add upgrade script for 3.0. to 3.1
- Upgrade old stack files so they will use "empty_quality" as the
"Not Supported" quality profile.
- Increase SettingVersion to 4
This was found by the materials team to be a better value. All UM3 profiles have 20 now. I've left the third-party machines intact which override the prime tower size but those that didn't override the prime tower size have their prime tower size altered as well.
These are now upgraded to version 3, meaning that they will have to increase their version numbers and remove any start_layers_at_same_position settings they define. None of these profiles define any start_layers_at_same_position so it's just the version number then.
Contributes to issue CURA-3479.