Commit graph

4061 commits

Author SHA1 Message Date
Ghostkeeper
ee0918f1d0
Merge branch '2.6' 2017-06-26 17:23:57 +02:00
Ghostkeeper
36cc21d31b
Rename Polypropylene to PP
They changed their mind.

Contributes to issue CURA-3960.
2017-06-26 17:20:59 +02:00
Jaime van Kessel
4ceb9f95cc Fixed weights of a few profiles
CURA-3845
2017-06-26 16:43:12 +02:00
Jaime van Kessel
b58abc91b3 Fixed names of 2 pp profiles
CURA-3960
2017-06-26 16:42:58 +02:00
Tim Kuipers
d31cacb69a Merge branch 'feature_prime_tower_purge' 2017-06-26 16:32:49 +02:00
Ghostkeeper
cefbe54843
Fix double infill overlap settings
These settings say the same, only the infill_overlap_mm one overwrites the infill_overlap setting. I therefore removed infill_overlap_mm so that the mm gets auto-calculated and none of the settings are overwritten any more (so they don't get greyed out).

Contributes to issue CURA-3960.
2017-06-26 16:30:26 +02:00
Jaime van Kessel
93f4a7e399 Fixed weights of a few profiles
CURA-3845
2017-06-26 16:28:53 +02:00
Ghostkeeper
a259217f52
Remove gradual infill for PP
This was delivered false by the materials team. It seems that in the end they decided to not use gradual infill for PP but only made the change in UM3, not UM2+. Removing gradual infill also requires me to set the infill density to 20% (the default).

Contributes to issue CURA-3960.
2017-06-26 16:15:40 +02:00
Tim Kuipers
e1d98d22f0 Merge branch 'master' into feature_prime_tower_purge 2017-06-26 16:11:41 +02:00
Lipu Fei
8a0afa9c32 Enable prime tower purge volume when prime tower and wipe are both enabled 2017-06-26 15:54:56 +02:00
Ghostkeeper
a5f3a1c983
Remove maximum warning for gradual infill step height
That 100mm figure was weird. 9cm was fine, but 10cm not? It's all going to print fine, really.

Contributes to issue CURA-3960.
2017-06-26 15:53:40 +02:00
Ghostkeeper
aee0cf7207
Make expand_lower_skins inherit from expand_skins_into_infill
And then also update the profiles to make the profiles end up at what it was originally (I confirmed this with the materials team).

Contributes to issue CURA-3960.
2017-06-26 15:47:49 +02:00
Ghostkeeper
b617c8be9c
Remove minimum warning value for z-hop height
It was giving a warning for 0.8mm polypropylene because that was set to 0.5mm hop. It was decided that a minimum value at all for z-hop is nonsense because you can just disable z-hop without getting a warning. I'm still setting it to zero because negative will still go wrong in your print.

Contributes to issue CURA-3960.
2017-06-26 15:27:27 +02:00
Ghostkeeper
c0b6df0bfa
Increase warning value for outer wall wipe distance
For polypropylene a wipe distance of twice the nozzle size is fine. Even required, since the material warps so much that it breaks open automatically if a breach starts to appear at the seam. For other warping materials this could also be a problem, so let's just increase the warning value.

Contributes to issue CURA-3960.
2017-06-26 15:14:22 +02:00
Jaime van Kessel
568b0c2285 Changed start code of Dagoma printer to indicate it's created by cura.
Originally it said it was created by Cura-by-dagoma, which is not the case. CURA-3966
2017-06-26 15:02:24 +02:00
Jaime van Kessel
71c262040f Merge branch 'master' of https://github.com/landru29/Cura 2017-06-26 14:58:37 +02:00
Ghostkeeper
c9aa8b4dfd
Put stand-by temperature back in optimised profiles
The stand-by temperature should be 175 for these profiles because the UM3 firmware levels the bed with that temperature. It should be 100 in the quality profiles because that's what the stand-by temperature should be when standing by while the other nozzle is printing.

Contributes to issue CURA-3960.
2017-06-26 14:58:14 +02:00
Jaime van Kessel
c36ab386fa Merge branch 'feature_tab_navigation' of https://github.com/fieldOfView/Cura 2017-06-26 14:39:12 +02:00
fieldOfView
0f9cfa0304 Fix tab order after expanding categories or using search
This reimplements the behavior of pressing tab/backtab to force the correct order of items in the listview.
2017-06-26 14:35:37 +02:00
Ghostkeeper
6cd7c8eb08
Fix stand-by temperature
The stand-by temperature in the material profiles is the temperature at which the build plate levelling should be done. The actual stand-by temperature in Cura should be 100, so these profiles have to overwrite the material profile then.

Contributes to issue CURA-3960.
2017-06-26 14:32:48 +02:00
Lipu Fei
d3bc625852 Fix prime tower purge description text
CURA-3094
2017-06-26 13:49:13 +02:00
fieldOfView
8917762ed5 Animate scrolling focussed item into view 2017-06-26 13:03:28 +02:00
fieldOfView
edee53b0b1 Scroll setting with active focus into view 2017-06-26 13:00:59 +02:00
Jaime van Kessel
572852d2d6 Merge branch '2.6' of github.com:Ultimaker/Cura 2017-06-26 11:49:48 +02:00
Jaime van Kessel
ffd17664d0 Fixed names of 2 pp profiles
CURA-3960
2017-06-26 11:49:18 +02:00
Lipu Fei
c2f9786303 Fix enable Prime Power Purge when Prime Tower Wipe is enabled
CURA-3094
2017-06-26 10:59:58 +02:00
Ghostkeeper
6088617453
Merge branch '2.6' 2017-06-26 10:34:58 +02:00
Ghostkeeper
9cc2b0fc82
Fix link to material name
The material was named generic_polypropylene, not generic_pp.

Contributes to issue CURA-3960.
2017-06-26 09:55:52 +02:00
Lipu Fei
af1e18df24 Enabled Prime Power Purge when Prime Tower Wipe is enabled
CURA-3094
2017-06-26 08:30:01 +02:00
Lipu Fei
15293964f8 Better description for Prime Tower Purge Volume
CURA-3094
2017-06-26 08:29:13 +02:00
Cyrille Meichel
f7a1c8dbb2 Add DiscoEasy printer (dagoma.fr) 2017-06-26 01:02:52 +02:00
Tim Kuipers
49e53c2cda Revert "dark layer view"
This reverts commit 67a4ec2a9e.
2017-06-23 17:25:53 +02:00
Ghostkeeper
7386b0bced
Remove translation for Material category
It looks very wierd to have the Material category label translated but not the rest of the categories. I don't know the proper translations for the rest, so I must remove this one. The label is left intact though.

Contributes to issue CURA-3950.
2017-06-23 16:50:36 +02:00
Ghostkeeper
8c9d051479
Re-enable Korean translations
They are complete now, as far as we agreed on (only the setting descriptions). They may now be re-enabled.

Contributes to issue CURA-3950.
2017-06-23 16:42:47 +02:00
Ghostkeeper
b68d8d98be
Update Korean translations
These files are directly copied from our Korean translator.

Contributes to issue CURA-3950.
2017-06-23 16:36:53 +02:00
Ghostkeeper
dc638fecbf
Mark 0.8mm CPE+ and PC profiles as experimental
These profiles have been tested and they are in the process of optimising them, but there is still some room for improvement there so this is supposed to lower the expectations of our users.

Contributes to issue CURA-3960.
2017-06-23 16:04:06 +02:00
Jaime van Kessel
ccb3f225ff Preheat now shows error color like all other input fields 2017-06-23 15:49:46 +02:00
Jaime van Kessel
78141cf330 Merge branch 'fix_layerview_small_windows' of https://github.com/fieldOfView/Cura 2017-06-23 15:11:57 +02:00
Ghostkeeper
269bc5f61f
Correct setting version of UM2+ polypropylene profiles
Missed that one, but thankfully the Cura log reminds us.

Contributes to issue CURA-3960.
2017-06-23 14:34:52 +02:00
Ghostkeeper
504bf5067c
Fix metadata of Ultimaker 2+ propylene profiles
Note that Git says that Fast was renamed to Verydraft, but in reality Fast was renamed to Draft and Draft was renamed to Verydraft.

Contributes to issue CURA-3960.
2017-06-23 14:24:14 +02:00
Ghostkeeper
25d2c10548
Optimise Ultimaker 2+ polypropylene profiles
These are optimised to the level of the materials: Anything that is common between quality profiles with the same material and nozzle gets bubbled to the profile for that material (per nozzle). It doesn't bubble any further (to the variant) because that could have an impact on the other profiles.
This basically only removes settings because where these settings then bubble to is the material profile in the fdm_materials repository. And a lot of settings are just removed because they are equal to the default.

Contributes to issue CURA-3960.
2017-06-23 14:15:27 +02:00
Lipu Fei
dbf0cf347c Default to 0 if we cannot find the theme
CURA-3873
2017-06-23 13:59:05 +02:00
Lipu Fei
2438effe0a Use 0.5 as max warning value for prime tower purge volume
CURA-3094

Purging more than 0.5mm^3 of material can be way too much, so we use
0.5mm^3 as the maximum warning value for the prime tower purge volume.
2017-06-23 13:34:19 +02:00
Lipu Fei
eb254b085a Use "Prime Tower Purge Volume" for setting label
CURA-3094
2017-06-23 13:34:09 +02:00
Lipu Fei
f3a9267fa6 Revert "Make LayerView work with "Purge" line type"
CURA-3094
2017-06-23 13:32:18 +02:00
Ghostkeeper
4b6f9be4ed
Correct names
The old names are what the materials team uses internally, and sorta old names too.

Contributes to issue CURA-3960.
2017-06-23 13:05:58 +02:00
Ghostkeeper
fa394a0171
Remove Not-Supported profiles for CPE+ and PC
They are now supported. This breaks the stacks of people who had these profiles active when they upgraded from 2.6.0 to 2.6.1, which causes them to get a screen of which printer they want to add, and they lose their current settings. But we decided that this use case is too slim to make an entire version upgrade for this patch-version release.

Contributes to issue CURA-3960.
2017-06-23 12:58:33 +02:00
Ghostkeeper
71197e9101
Optimise new profiles
This removes all settings that are equal to the defaults. Some settings are 'common' between all profiles of the same material. I've let those settings bubble up to the material profiles but that change is then obviously only apparent in the fdm_materials repository.

Contributes to issue CURA-3960.
2017-06-23 12:45:40 +02:00
Ghostkeeper
5f6894c523
Add PP profiles for UM2+
These new profiles are directly copied from what the material team provides. They should now be optimised.

Contributes to issue CURA-3960.
2017-06-23 11:14:21 +02:00
Ghostkeeper
a8f2f6560f
Add PP profiles
These are copied from the materials team and should now be optimised.

Contributes to issue CURA-3960.
2017-06-23 11:07:25 +02:00