The top/bottom speed is reduced by 80% to allow for better cooling of the top layers. This reduces pillowing. The line width is increased by 80% to maintain the flow equalization. PP-95
Conflicts:
plugins/SimulationView/SimulationPass.py -> Reverted layer view optimisation in Master while some whitespace changed in Arachne.
resources/definitions -> Bunch of conflicts with profile updates.
resources/quality -> Bunch of conflicts with profile updates.
resources/texts/change_log.txt -> Removed the Arachne change log (as they are internal versions). It'll have to be re-added when we release this version as stable.
Since the setting version 18 is used in the arachne beta build, we decided to make the the setting version to 19 in the normal releases, so that we make sure that projects made in arachne beta won't use any version upgrade scripts if a user attempts to open them in 4.12.
CURA-8510
We now have version 18, where Flsun Super Racer has customised profiles.
Nothing changes in the built-in profiles. It only needs a change in the machine instances.
Contributes to issue CURA-8510.
Although it is not entirely sure yet, we are fairly certain that libArachne release will have
a setting version of 18, so it is changed by this commit. With this change, the VersionUpgrader
will be properly triggered.
Contributes to CURA-7683 and CURA-7656
We have a change now that requires a version upgrade. This triggers all profiles to update for the user, and we must update accordingly in the built-in profiles.
Contributes to issue CURA-7118.
Removal of all final and initial print temperature offsets, and huge increase in first layer print temperature. These changes should greatly improve first layer extrusion.
This reverts commit 9432252de4. It was assuming the wrong default speed_print value of 60. It's not always 60. We need to find a different solution or modify the script.
Reverts the fix for issue CURA-5342.
- Add a new field "variant" in "metadata" section for quality profiles.
"material" will only contain values such as "generic_abs", and
"variant" will contain values such as "0.25 mm", "AA 0.4", etc.
- Reformat "metadata" section to have the following order:
- setting_version
- type
- quality_type
- weight
- global_quality
- material
- variant
Changed infill to Cross3D 10% (no gradual) for a more isotropic flexibility of parts. Cross3D also prints without travels (if possible) and looks great.
CURA-4451
- Add upgrade script for 3.0. to 3.1
- Upgrade old stack files so they will use "empty_quality" as the
"Not Supported" quality profile.
- Increase SettingVersion to 4
The stand-by temperature should be 175 for these profiles because the UM3 firmware levels the bed with that temperature. It should be 100 in the quality profiles because that's what the stand-by temperature should be when standing by while the other nozzle is printing.
Contributes to issue CURA-3960.
This removes all settings that are equal to the defaults. Some settings are 'common' between all profiles of the same material. I've let those settings bubble up to the material profiles but that change is then obviously only apparent in the fdm_materials repository.
Contributes to issue CURA-3960.
These profiles are improved by the materials team. This is directly copied from them and should now be optimised for our use.
Contributes to issue CURA-3960.
For the 0.8mm profiles the variants specify 5%, so we remove it from those profiles. The 0.4mm variants specify 15% so for those we need to override it.
The UM3 definition sets the setting to 3mm. Nothing else sets it to another value except FDM Printer. I left the UM3 setting in and removed all travel_avoid_distance settings in the UM3 profiles.