📝 Some settings units

This commit is contained in:
Scott Lahteine 2023-10-06 15:59:27 -05:00
parent 6cdb3fb1d1
commit 706bf3aa04
354 changed files with 6371 additions and 6371 deletions

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 360 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 360 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 60 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 10 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 60 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 10 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 60 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 60 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2449,7 +2449,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2649,7 +2649,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 60 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 10 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 60 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 10 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 60 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 60 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2440,7 +2440,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2640,7 +2640,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 60 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 10 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 60 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 10 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 60 // Seconds
#define WATCH_TEMP_INCREASE 5 // Degrees Celsius
#define WATCH_TEMP_PERIOD 60 // (seconds)
#define WATCH_TEMP_INCREASE 5 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 60 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 5 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 60 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 5 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 180 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 180 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 60 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 10 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 60 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 10 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 60 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 5 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 60 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 5 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 180 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 180 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 12 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 12 // (°C)
#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 30 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 30 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 5 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 5 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 80 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 80 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 12 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 12 // (°C)
#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 30 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 30 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 5 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 5 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 80 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 80 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
#define NO_TIMEOUTS 1000 // Milliseconds
#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 180 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 180 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 180 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 180 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 180 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 180 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 180 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 180 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 180 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 180 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 180 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 180 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 10 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 10 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 4 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 40 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 40 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 8 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 8 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 20 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 20 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -309,8 +309,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -332,50 +332,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2444,7 +2444,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2644,7 +2644,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 45 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 45 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 2 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 60 // Seconds
#define WATCH_TEMP_INCREASE 1 // Degrees Celsius
#define WATCH_TEMP_PERIOD 60 // (seconds)
#define WATCH_TEMP_INCREASE 1 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 60 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 60 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 3 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 1 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 1 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 60 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 60 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 2 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 45 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 45 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2436,7 +2436,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2636,7 +2636,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 180 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 180 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 180 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 180 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 180 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 180 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 180 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 180 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 180 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 180 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 180 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 180 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2441,7 +2441,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2641,7 +2641,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 50 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 5 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 50 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 5 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 30 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 30 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2440,7 +2440,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2640,7 +2640,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 180 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 180 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 180 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 180 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2440,7 +2440,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2640,7 +2640,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2447,7 +2447,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2647,7 +2647,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
#define NO_TIMEOUTS 1000 // Milliseconds
#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2440,7 +2440,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2640,7 +2640,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2438,7 +2438,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2638,7 +2638,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 4 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 600 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 600 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 4 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 600 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 600 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 180 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 180 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 180 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 180 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2440,7 +2440,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2640,7 +2640,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 4 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 600 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 600 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 4 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 600 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 600 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 60 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 10 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 60 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 10 // (°C)
#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 50 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 50 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 50 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 50 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 180 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 180 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2444,7 +2444,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2644,7 +2644,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 60 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 10 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 60 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 10 // (°C)
#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 50 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 50 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 50 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 50 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 180 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 180 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2446,7 +2446,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2646,7 +2646,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 4 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 4 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 4 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 4 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2440,7 +2440,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2640,7 +2640,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
#define NO_TIMEOUTS 1000 // Milliseconds
#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 120 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 120 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 4 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 4 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 180 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 180 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 180 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 180 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 60 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 60 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 60 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 60 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 180 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 180 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 180 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 180 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2440,7 +2440,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2640,7 +2640,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 180 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 180 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 180 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 180 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2440,7 +2440,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2640,7 +2640,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 60 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 60 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 100 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 100 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 60 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 60 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 100 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 100 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2440,7 +2440,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2640,7 +2640,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 180 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 180 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 180 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 180 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2440,7 +2440,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2640,7 +2640,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 60 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 60 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
//#define ADVANCED_OK

View file

@ -304,8 +304,8 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
#define THERMAL_PROTECTION_PERIOD 40 // (seconds)
#define THERMAL_PROTECTION_HYSTERESIS 4 // (°C)
//#define ADAPTIVE_FAN_SLOWING // Slow down the part-cooling fan if the temperature drops
#if ENABLED(ADAPTIVE_FAN_SLOWING)
@ -327,50 +327,50 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 40 // Seconds
#define WATCH_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_TEMP_PERIOD 40 // (seconds)
#define WATCH_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the bed are just as above for hotends.
*/
#if ENABLED(THERMAL_PROTECTION_BED)
#define THERMAL_PROTECTION_BED_PERIOD 180 // Seconds
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_BED_PERIOD 180 // (seconds)
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // (°C)
/**
* As described above, except for the bed (M140/M190/M303).
*/
#define WATCH_BED_TEMP_PERIOD 180 // Seconds
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_BED_TEMP_PERIOD 180 // (seconds)
#define WATCH_BED_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the heated chamber.
*/
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // (seconds)
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // (°C)
/**
* Heated chamber watch settings (M141/M191).
*/
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
#define WATCH_CHAMBER_TEMP_PERIOD 60 // (seconds)
#define WATCH_CHAMBER_TEMP_INCREASE 2 // (°C)
#endif
/**
* Thermal Protection parameters for the laser cooler.
*/
#if ENABLED(THERMAL_PROTECTION_COOLER)
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // Degrees Celsius
#define THERMAL_PROTECTION_COOLER_PERIOD 10 // (seconds)
#define THERMAL_PROTECTION_COOLER_HYSTERESIS 3 // (°C)
/**
* Laser cooling watch settings (M143/M193).
*/
#define WATCH_COOLER_TEMP_PERIOD 60 // Seconds
#define WATCH_COOLER_TEMP_INCREASE 3 // Degrees Celsius
#define WATCH_COOLER_TEMP_PERIOD 60 // (seconds)
#define WATCH_COOLER_TEMP_INCREASE 3 // (°C)
#endif
#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
@ -2439,7 +2439,7 @@
// Height above Z=0.0 to raise the nozzle. Lowering this can help the probe to heat faster.
// Note: The Z=0.0 offset is determined by the probe Z offset (e.g., as set with M851 Z).
#define PTC_PROBE_HEATING_OFFSET 0.5
#define PTC_PROBE_HEATING_OFFSET 0.5 // (mm)
#endif
#endif // PTC_PROBE || PTC_BED || PTC_HOTEND
@ -2639,7 +2639,7 @@
// Therefore some clients abort after 30 seconds in a timeout.
// Some other clients start sending commands while receiving a 'wait'.
// This "wait" is only sent when the buffer is empty. 1 second is a good value here.
//#define NO_TIMEOUTS 1000 // Milliseconds
//#define NO_TIMEOUTS 1000 // (ms)
// Some clients will have this feature soon. This could make the NO_TIMEOUTS unnecessary.
#define ADVANCED_OK