PROBE user thermistor

This commit is contained in:
Scott Lahteine 2021-02-07 02:24:31 -06:00
parent a0ebbf3095
commit 6c3feddf45
467 changed files with 2721 additions and 687 deletions

View file

@ -1776,7 +1776,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 190
#define PREHEAT_1_TEMP_BED 45

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3360,7 +3366,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1772,7 +1772,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 190
#define PREHEAT_1_TEMP_BED 60

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1721,7 +1721,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 180
#define PREHEAT_1_TEMP_BED 70

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3360,7 +3366,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1720,7 +1720,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 180
#define PREHEAT_1_TEMP_BED 70

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3358,7 +3364,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1731,7 +1731,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 180
#define PREHEAT_1_TEMP_BED 70

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1719,7 +1719,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 180
#define PREHEAT_1_TEMP_BED 70

View file

@ -1720,7 +1720,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 180
#define PREHEAT_1_TEMP_BED 70

View file

@ -1721,7 +1721,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 200
#define PREHEAT_1_TEMP_BED 60

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1729,7 +1729,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 210
#define PREHEAT_1_TEMP_BED 60

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3360,7 +3366,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1724,7 +1724,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 195
#define PREHEAT_1_TEMP_BED 60

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1723,7 +1723,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 195
#define PREHEAT_1_TEMP_BED 60

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1723,7 +1723,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 180
#define PREHEAT_1_TEMP_BED 70

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1720,7 +1720,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 200
#define PREHEAT_1_TEMP_BED 60

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1720,7 +1720,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 200
#define PREHEAT_1_TEMP_BED 60

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1720,7 +1720,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 200
#define PREHEAT_1_TEMP_BED 60

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1720,7 +1720,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 200
#define PREHEAT_1_TEMP_BED 60

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1721,7 +1721,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 180
#define PREHEAT_1_TEMP_BED 70

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1726,7 +1726,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 210
#define PREHEAT_1_TEMP_BED 60

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1721,7 +1721,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 180
#define PREHEAT_1_TEMP_BED 70

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1686,7 +1686,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 180
#define PREHEAT_1_TEMP_BED 70

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1722,7 +1722,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 195
#define PREHEAT_1_TEMP_BED 60

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1721,7 +1721,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 180
#define PREHEAT_1_TEMP_BED 70

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1721,7 +1721,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 180
#define PREHEAT_1_TEMP_BED 60

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)

View file

@ -1723,7 +1723,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 180
#define PREHEAT_1_TEMP_BED 70

View file

@ -1742,7 +1742,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 180
#define PREHEAT_1_TEMP_BED 70

View file

@ -1726,7 +1726,9 @@
// @section temperature
// Preheat Constants
//
// Preheat Constants - Up to 5 are supported without changes
//
#define PREHEAT_1_LABEL "PLA"
#define PREHEAT_1_TEMP_HOTEND 180
#define PREHEAT_1_TEMP_BED 70

View file

@ -113,6 +113,12 @@
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
@ -331,7 +337,7 @@
* High Temperature Thermistor Support
*
* Thermistors able to support high temperature tend to have a hard time getting
* good readings at room and lower temperatures. This means HEATER_X_RAW_LO_TEMP
* good readings at room and lower temperatures. This means TEMP_SENSOR_X_RAW_LO_TEMP
* will probably be caught when the heating element first turns on during the
* preheating process, which will trigger a min_temp_error as a safety measure
* and force stop everything.
@ -3359,7 +3365,8 @@
#endif
/**
* User-defined menu items that execute custom GCode
* User-defined menu items to run custom G-code.
* Up to 25 may be defined, but the actual number is LCD-dependent.
*/
//#define CUSTOM_USER_MENUS
#if ENABLED(CUSTOM_USER_MENUS)