mirror of
https://github.com/Motorhead1991/qemu.git
synced 2025-08-02 07:13:54 -06:00

core::ffi::c_* types were introduced in Rust 1.64.0. Use the older types in std::os::raw, which are now aliases of the types in core::ffi. There is no need to compile QEMU as no_std, so this is acceptable as long as we support a version of Debian with Rust 1.63.0. Reviewed-by: Zhao Liu <zhao1.liu@intel.com> Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
588 lines
23 KiB
Rust
588 lines
23 KiB
Rust
// Copyright 2024, Linaro Limited
|
|
// Author(s): Manos Pitsidianakis <manos.pitsidianakis@linaro.org>
|
|
// SPDX-License-Identifier: GPL-2.0-or-later
|
|
//
|
|
// PL011 QEMU Device Model
|
|
//
|
|
// This library implements a device model for the PrimeCell® UART (PL011)
|
|
// device in QEMU.
|
|
//
|
|
#![doc = include_str!("../README.md")]
|
|
//! # Library crate
|
|
//!
|
|
//! See [`PL011State`](crate::device::PL011State) for the device model type and
|
|
//! the [`registers`] module for register types.
|
|
|
|
#![deny(
|
|
rustdoc::broken_intra_doc_links,
|
|
rustdoc::redundant_explicit_links,
|
|
clippy::correctness,
|
|
clippy::suspicious,
|
|
clippy::complexity,
|
|
clippy::perf,
|
|
clippy::cargo,
|
|
clippy::nursery,
|
|
clippy::style,
|
|
// restriction group
|
|
clippy::dbg_macro,
|
|
clippy::as_underscore,
|
|
clippy::assertions_on_result_states,
|
|
// pedantic group
|
|
clippy::doc_markdown,
|
|
clippy::borrow_as_ptr,
|
|
clippy::cast_lossless,
|
|
clippy::option_if_let_else,
|
|
clippy::missing_const_for_fn,
|
|
clippy::cognitive_complexity,
|
|
clippy::missing_safety_doc,
|
|
)]
|
|
#![allow(clippy::result_unit_err)]
|
|
|
|
extern crate bilge;
|
|
extern crate bilge_impl;
|
|
extern crate qemu_api;
|
|
|
|
pub mod device;
|
|
pub mod device_class;
|
|
pub mod memory_ops;
|
|
|
|
pub const TYPE_PL011: &::std::ffi::CStr = c"pl011";
|
|
pub const TYPE_PL011_LUMINARY: &::std::ffi::CStr = c"pl011_luminary";
|
|
|
|
/// Offset of each register from the base memory address of the device.
|
|
///
|
|
/// # Source
|
|
/// ARM DDI 0183G, Table 3-1 p.3-3
|
|
#[doc(alias = "offset")]
|
|
#[allow(non_camel_case_types)]
|
|
#[repr(u64)]
|
|
#[derive(Debug)]
|
|
pub enum RegisterOffset {
|
|
/// Data Register
|
|
///
|
|
/// A write to this register initiates the actual data transmission
|
|
#[doc(alias = "UARTDR")]
|
|
DR = 0x000,
|
|
/// Receive Status Register or Error Clear Register
|
|
#[doc(alias = "UARTRSR")]
|
|
#[doc(alias = "UARTECR")]
|
|
RSR = 0x004,
|
|
/// Flag Register
|
|
///
|
|
/// A read of this register shows if transmission is complete
|
|
#[doc(alias = "UARTFR")]
|
|
FR = 0x018,
|
|
/// Fractional Baud Rate Register
|
|
///
|
|
/// responsible for baud rate speed
|
|
#[doc(alias = "UARTFBRD")]
|
|
FBRD = 0x028,
|
|
/// `IrDA` Low-Power Counter Register
|
|
#[doc(alias = "UARTILPR")]
|
|
ILPR = 0x020,
|
|
/// Integer Baud Rate Register
|
|
///
|
|
/// Responsible for baud rate speed
|
|
#[doc(alias = "UARTIBRD")]
|
|
IBRD = 0x024,
|
|
/// line control register (data frame format)
|
|
#[doc(alias = "UARTLCR_H")]
|
|
LCR_H = 0x02C,
|
|
/// Toggle UART, transmission or reception
|
|
#[doc(alias = "UARTCR")]
|
|
CR = 0x030,
|
|
/// Interrupt FIFO Level Select Register
|
|
#[doc(alias = "UARTIFLS")]
|
|
FLS = 0x034,
|
|
/// Interrupt Mask Set/Clear Register
|
|
#[doc(alias = "UARTIMSC")]
|
|
IMSC = 0x038,
|
|
/// Raw Interrupt Status Register
|
|
#[doc(alias = "UARTRIS")]
|
|
RIS = 0x03C,
|
|
/// Masked Interrupt Status Register
|
|
#[doc(alias = "UARTMIS")]
|
|
MIS = 0x040,
|
|
/// Interrupt Clear Register
|
|
#[doc(alias = "UARTICR")]
|
|
ICR = 0x044,
|
|
/// DMA control Register
|
|
#[doc(alias = "UARTDMACR")]
|
|
DMACR = 0x048,
|
|
///// Reserved, offsets `0x04C` to `0x07C`.
|
|
//Reserved = 0x04C,
|
|
}
|
|
|
|
impl core::convert::TryFrom<u64> for RegisterOffset {
|
|
type Error = u64;
|
|
|
|
fn try_from(value: u64) -> Result<Self, Self::Error> {
|
|
macro_rules! case {
|
|
($($discriminant:ident),*$(,)*) => {
|
|
/* check that matching on all macro arguments compiles, which means we are not
|
|
* missing any enum value; if the type definition ever changes this will stop
|
|
* compiling.
|
|
*/
|
|
const fn _assert_exhaustive(val: RegisterOffset) {
|
|
match val {
|
|
$(RegisterOffset::$discriminant => (),)*
|
|
}
|
|
}
|
|
|
|
match value {
|
|
$(x if x == Self::$discriminant as u64 => Ok(Self::$discriminant),)*
|
|
_ => Err(value),
|
|
}
|
|
}
|
|
}
|
|
case! { DR, RSR, FR, FBRD, ILPR, IBRD, LCR_H, CR, FLS, IMSC, RIS, MIS, ICR, DMACR }
|
|
}
|
|
}
|
|
|
|
pub mod registers {
|
|
//! Device registers exposed as typed structs which are backed by arbitrary
|
|
//! integer bitmaps. [`Data`], [`Control`], [`LineControl`], etc.
|
|
//!
|
|
//! All PL011 registers are essentially 32-bit wide, but are typed here as
|
|
//! bitmaps with only the necessary width. That is, if a struct bitmap
|
|
//! in this module is for example 16 bits long, it should be conceived
|
|
//! as a 32-bit register where the unmentioned higher bits are always
|
|
//! unused thus treated as zero when read or written.
|
|
use bilge::prelude::*;
|
|
|
|
// TODO: FIFO Mode has different semantics
|
|
/// Data Register, `UARTDR`
|
|
///
|
|
/// The `UARTDR` register is the data register.
|
|
///
|
|
/// For words to be transmitted:
|
|
///
|
|
/// - if the FIFOs are enabled, data written to this location is pushed onto
|
|
/// the transmit
|
|
/// FIFO
|
|
/// - if the FIFOs are not enabled, data is stored in the transmitter
|
|
/// holding register (the
|
|
/// bottom word of the transmit FIFO).
|
|
///
|
|
/// The write operation initiates transmission from the UART. The data is
|
|
/// prefixed with a start bit, appended with the appropriate parity bit
|
|
/// (if parity is enabled), and a stop bit. The resultant word is then
|
|
/// transmitted.
|
|
///
|
|
/// For received words:
|
|
///
|
|
/// - if the FIFOs are enabled, the data byte and the 4-bit status (break,
|
|
/// frame, parity,
|
|
/// and overrun) is pushed onto the 12-bit wide receive FIFO
|
|
/// - if the FIFOs are not enabled, the data byte and status are stored in
|
|
/// the receiving
|
|
/// holding register (the bottom word of the receive FIFO).
|
|
///
|
|
/// The received data byte is read by performing reads from the `UARTDR`
|
|
/// register along with the corresponding status information. The status
|
|
/// information can also be read by a read of the `UARTRSR/UARTECR`
|
|
/// register.
|
|
///
|
|
/// # Note
|
|
///
|
|
/// You must disable the UART before any of the control registers are
|
|
/// reprogrammed. When the UART is disabled in the middle of
|
|
/// transmission or reception, it completes the current character before
|
|
/// stopping.
|
|
///
|
|
/// # Source
|
|
/// ARM DDI 0183G 3.3.1 Data Register, UARTDR
|
|
#[bitsize(16)]
|
|
#[derive(Clone, Copy, DebugBits, FromBits)]
|
|
#[doc(alias = "UARTDR")]
|
|
pub struct Data {
|
|
_reserved: u4,
|
|
pub data: u8,
|
|
pub framing_error: bool,
|
|
pub parity_error: bool,
|
|
pub break_error: bool,
|
|
pub overrun_error: bool,
|
|
}
|
|
|
|
// TODO: FIFO Mode has different semantics
|
|
/// Receive Status Register / Error Clear Register, `UARTRSR/UARTECR`
|
|
///
|
|
/// The UARTRSR/UARTECR register is the receive status register/error clear
|
|
/// register. Receive status can also be read from the `UARTRSR`
|
|
/// register. If the status is read from this register, then the status
|
|
/// information for break, framing and parity corresponds to the
|
|
/// data character read from the [Data register](Data), `UARTDR` prior to
|
|
/// reading the UARTRSR register. The status information for overrun is
|
|
/// set immediately when an overrun condition occurs.
|
|
///
|
|
///
|
|
/// # Note
|
|
/// The received data character must be read first from the [Data
|
|
/// Register](Data), `UARTDR` before reading the error status associated
|
|
/// with that data character from the `UARTRSR` register. This read
|
|
/// sequence cannot be reversed, because the `UARTRSR` register is
|
|
/// updated only when a read occurs from the `UARTDR` register. However,
|
|
/// the status information can also be obtained by reading the `UARTDR`
|
|
/// register
|
|
///
|
|
/// # Source
|
|
/// ARM DDI 0183G 3.3.2 Receive Status Register/Error Clear Register,
|
|
/// UARTRSR/UARTECR
|
|
#[bitsize(8)]
|
|
#[derive(Clone, Copy, DebugBits, FromBits)]
|
|
pub struct ReceiveStatusErrorClear {
|
|
pub framing_error: bool,
|
|
pub parity_error: bool,
|
|
pub break_error: bool,
|
|
pub overrun_error: bool,
|
|
_reserved_unpredictable: u4,
|
|
}
|
|
|
|
impl ReceiveStatusErrorClear {
|
|
pub fn reset(&mut self) {
|
|
// All the bits are cleared to 0 on reset.
|
|
*self = 0.into();
|
|
}
|
|
}
|
|
|
|
impl Default for ReceiveStatusErrorClear {
|
|
fn default() -> Self {
|
|
0.into()
|
|
}
|
|
}
|
|
|
|
#[bitsize(16)]
|
|
#[derive(Clone, Copy, DebugBits, FromBits)]
|
|
/// Flag Register, `UARTFR`
|
|
#[doc(alias = "UARTFR")]
|
|
pub struct Flags {
|
|
/// CTS Clear to send. This bit is the complement of the UART clear to
|
|
/// send, `nUARTCTS`, modem status input. That is, the bit is 1
|
|
/// when `nUARTCTS` is LOW.
|
|
pub clear_to_send: bool,
|
|
/// DSR Data set ready. This bit is the complement of the UART data set
|
|
/// ready, `nUARTDSR`, modem status input. That is, the bit is 1 when
|
|
/// `nUARTDSR` is LOW.
|
|
pub data_set_ready: bool,
|
|
/// DCD Data carrier detect. This bit is the complement of the UART data
|
|
/// carrier detect, `nUARTDCD`, modem status input. That is, the bit is
|
|
/// 1 when `nUARTDCD` is LOW.
|
|
pub data_carrier_detect: bool,
|
|
/// BUSY UART busy. If this bit is set to 1, the UART is busy
|
|
/// transmitting data. This bit remains set until the complete
|
|
/// byte, including all the stop bits, has been sent from the
|
|
/// shift register. This bit is set as soon as the transmit FIFO
|
|
/// becomes non-empty, regardless of whether the UART is enabled
|
|
/// or not.
|
|
pub busy: bool,
|
|
/// RXFE Receive FIFO empty. The meaning of this bit depends on the
|
|
/// state of the FEN bit in the UARTLCR_H register. If the FIFO
|
|
/// is disabled, this bit is set when the receive holding
|
|
/// register is empty. If the FIFO is enabled, the RXFE bit is
|
|
/// set when the receive FIFO is empty.
|
|
pub receive_fifo_empty: bool,
|
|
/// TXFF Transmit FIFO full. The meaning of this bit depends on the
|
|
/// state of the FEN bit in the UARTLCR_H register. If the FIFO
|
|
/// is disabled, this bit is set when the transmit holding
|
|
/// register is full. If the FIFO is enabled, the TXFF bit is
|
|
/// set when the transmit FIFO is full.
|
|
pub transmit_fifo_full: bool,
|
|
/// RXFF Receive FIFO full. The meaning of this bit depends on the state
|
|
/// of the FEN bit in the UARTLCR_H register. If the FIFO is
|
|
/// disabled, this bit is set when the receive holding register
|
|
/// is full. If the FIFO is enabled, the RXFF bit is set when
|
|
/// the receive FIFO is full.
|
|
pub receive_fifo_full: bool,
|
|
/// Transmit FIFO empty. The meaning of this bit depends on the state of
|
|
/// the FEN bit in the [Line Control register](LineControl),
|
|
/// `UARTLCR_H`. If the FIFO is disabled, this bit is set when the
|
|
/// transmit holding register is empty. If the FIFO is enabled,
|
|
/// the TXFE bit is set when the transmit FIFO is empty. This
|
|
/// bit does not indicate if there is data in the transmit shift
|
|
/// register.
|
|
pub transmit_fifo_empty: bool,
|
|
/// `RI`, is `true` when `nUARTRI` is `LOW`.
|
|
pub ring_indicator: bool,
|
|
_reserved_zero_no_modify: u7,
|
|
}
|
|
|
|
impl Flags {
|
|
pub fn reset(&mut self) {
|
|
// After reset TXFF, RXFF, and BUSY are 0, and TXFE and RXFE are 1
|
|
self.set_receive_fifo_full(false);
|
|
self.set_transmit_fifo_full(false);
|
|
self.set_busy(false);
|
|
self.set_receive_fifo_empty(true);
|
|
self.set_transmit_fifo_empty(true);
|
|
}
|
|
}
|
|
|
|
impl Default for Flags {
|
|
fn default() -> Self {
|
|
let mut ret: Self = 0.into();
|
|
ret.reset();
|
|
ret
|
|
}
|
|
}
|
|
|
|
#[bitsize(16)]
|
|
#[derive(Clone, Copy, DebugBits, FromBits)]
|
|
/// Line Control Register, `UARTLCR_H`
|
|
#[doc(alias = "UARTLCR_H")]
|
|
pub struct LineControl {
|
|
/// 15:8 - Reserved, do not modify, read as zero.
|
|
_reserved_zero_no_modify: u8,
|
|
/// 7 SPS Stick parity select.
|
|
/// 0 = stick parity is disabled
|
|
/// 1 = either:
|
|
/// • if the EPS bit is 0 then the parity bit is transmitted and checked
|
|
/// as a 1 • if the EPS bit is 1 then the parity bit is
|
|
/// transmitted and checked as a 0. This bit has no effect when
|
|
/// the PEN bit disables parity checking and generation. See Table 3-11
|
|
/// on page 3-14 for the parity truth table.
|
|
pub sticky_parity: bool,
|
|
/// WLEN Word length. These bits indicate the number of data bits
|
|
/// transmitted or received in a frame as follows: b11 = 8 bits
|
|
/// b10 = 7 bits
|
|
/// b01 = 6 bits
|
|
/// b00 = 5 bits.
|
|
pub word_length: WordLength,
|
|
/// FEN Enable FIFOs:
|
|
/// 0 = FIFOs are disabled (character mode) that is, the FIFOs become
|
|
/// 1-byte-deep holding registers 1 = transmit and receive FIFO
|
|
/// buffers are enabled (FIFO mode).
|
|
pub fifos_enabled: Mode,
|
|
/// 3 STP2 Two stop bits select. If this bit is set to 1, two stop bits
|
|
/// are transmitted at the end of the frame. The receive
|
|
/// logic does not check for two stop bits being received.
|
|
pub two_stops_bits: bool,
|
|
/// EPS Even parity select. Controls the type of parity the UART uses
|
|
/// during transmission and reception:
|
|
/// - 0 = odd parity. The UART generates or checks for an odd number of
|
|
/// 1s in the data and parity bits.
|
|
/// - 1 = even parity. The UART generates or checks for an even number
|
|
/// of 1s in the data and parity bits.
|
|
/// This bit has no effect when the `PEN` bit disables parity checking
|
|
/// and generation. See Table 3-11 on page 3-14 for the parity
|
|
/// truth table.
|
|
pub parity: Parity,
|
|
/// 1 PEN Parity enable:
|
|
///
|
|
/// - 0 = parity is disabled and no parity bit added to the data frame
|
|
/// - 1 = parity checking and generation is enabled.
|
|
///
|
|
/// See Table 3-11 on page 3-14 for the parity truth table.
|
|
pub parity_enabled: bool,
|
|
/// BRK Send break.
|
|
///
|
|
/// If this bit is set to `1`, a low-level is continually output on the
|
|
/// `UARTTXD` output, after completing transmission of the
|
|
/// current character. For the proper execution of the break command,
|
|
/// the software must set this bit for at least two complete
|
|
/// frames. For normal use, this bit must be cleared to `0`.
|
|
pub send_break: bool,
|
|
}
|
|
|
|
impl LineControl {
|
|
pub fn reset(&mut self) {
|
|
// All the bits are cleared to 0 when reset.
|
|
*self = 0.into();
|
|
}
|
|
}
|
|
|
|
impl Default for LineControl {
|
|
fn default() -> Self {
|
|
0.into()
|
|
}
|
|
}
|
|
|
|
#[bitsize(1)]
|
|
#[derive(Clone, Copy, Debug, Eq, FromBits, PartialEq)]
|
|
/// `EPS` "Even parity select", field of [Line Control
|
|
/// register](LineControl).
|
|
pub enum Parity {
|
|
/// - 0 = odd parity. The UART generates or checks for an odd number of
|
|
/// 1s in the data and parity bits.
|
|
Odd = 0,
|
|
/// - 1 = even parity. The UART generates or checks for an even number
|
|
/// of 1s in the data and parity bits.
|
|
Even = 1,
|
|
}
|
|
|
|
#[bitsize(1)]
|
|
#[derive(Clone, Copy, Debug, Eq, FromBits, PartialEq)]
|
|
/// `FEN` "Enable FIFOs" or Device mode, field of [Line Control
|
|
/// register](LineControl).
|
|
pub enum Mode {
|
|
/// 0 = FIFOs are disabled (character mode) that is, the FIFOs become
|
|
/// 1-byte-deep holding registers
|
|
Character = 0,
|
|
/// 1 = transmit and receive FIFO buffers are enabled (FIFO mode).
|
|
FIFO = 1,
|
|
}
|
|
|
|
impl From<Mode> for bool {
|
|
fn from(val: Mode) -> Self {
|
|
matches!(val, Mode::FIFO)
|
|
}
|
|
}
|
|
|
|
#[bitsize(2)]
|
|
#[derive(Clone, Copy, Debug, Eq, FromBits, PartialEq)]
|
|
/// `WLEN` Word length, field of [Line Control register](LineControl).
|
|
///
|
|
/// These bits indicate the number of data bits transmitted or received in a
|
|
/// frame as follows:
|
|
pub enum WordLength {
|
|
/// b11 = 8 bits
|
|
_8Bits = 0b11,
|
|
/// b10 = 7 bits
|
|
_7Bits = 0b10,
|
|
/// b01 = 6 bits
|
|
_6Bits = 0b01,
|
|
/// b00 = 5 bits.
|
|
_5Bits = 0b00,
|
|
}
|
|
|
|
/// Control Register, `UARTCR`
|
|
///
|
|
/// The `UARTCR` register is the control register. All the bits are cleared
|
|
/// to `0` on reset except for bits `9` and `8` that are set to `1`.
|
|
///
|
|
/// # Source
|
|
/// ARM DDI 0183G, 3.3.8 Control Register, `UARTCR`, Table 3-12
|
|
#[bitsize(16)]
|
|
#[doc(alias = "UARTCR")]
|
|
#[derive(Clone, Copy, DebugBits, FromBits)]
|
|
pub struct Control {
|
|
/// `UARTEN` UART enable: 0 = UART is disabled. If the UART is disabled
|
|
/// in the middle of transmission or reception, it completes the current
|
|
/// character before stopping. 1 = the UART is enabled. Data
|
|
/// transmission and reception occurs for either UART signals or SIR
|
|
/// signals depending on the setting of the SIREN bit.
|
|
pub enable_uart: bool,
|
|
/// `SIREN` `SIR` enable: 0 = IrDA SIR ENDEC is disabled. `nSIROUT`
|
|
/// remains LOW (no light pulse generated), and signal transitions on
|
|
/// SIRIN have no effect. 1 = IrDA SIR ENDEC is enabled. Data is
|
|
/// transmitted and received on nSIROUT and SIRIN. UARTTXD remains HIGH,
|
|
/// in the marking state. Signal transitions on UARTRXD or modem status
|
|
/// inputs have no effect. This bit has no effect if the UARTEN bit
|
|
/// disables the UART.
|
|
pub enable_sir: bool,
|
|
/// `SIRLP` SIR low-power IrDA mode. This bit selects the IrDA encoding
|
|
/// mode. If this bit is cleared to 0, low-level bits are transmitted as
|
|
/// an active high pulse with a width of 3/ 16th of the bit period. If
|
|
/// this bit is set to 1, low-level bits are transmitted with a pulse
|
|
/// width that is 3 times the period of the IrLPBaud16 input signal,
|
|
/// regardless of the selected bit rate. Setting this bit uses less
|
|
/// power, but might reduce transmission distances.
|
|
pub sir_lowpower_irda_mode: u1,
|
|
/// Reserved, do not modify, read as zero.
|
|
_reserved_zero_no_modify: u4,
|
|
/// `LBE` Loopback enable. If this bit is set to 1 and the SIREN bit is
|
|
/// set to 1 and the SIRTEST bit in the Test Control register, UARTTCR
|
|
/// on page 4-5 is set to 1, then the nSIROUT path is inverted, and fed
|
|
/// through to the SIRIN path. The SIRTEST bit in the test register must
|
|
/// be set to 1 to override the normal half-duplex SIR operation. This
|
|
/// must be the requirement for accessing the test registers during
|
|
/// normal operation, and SIRTEST must be cleared to 0 when loopback
|
|
/// testing is finished. This feature reduces the amount of external
|
|
/// coupling required during system test. If this bit is set to 1, and
|
|
/// the SIRTEST bit is set to 0, the UARTTXD path is fed through to the
|
|
/// UARTRXD path. In either SIR mode or UART mode, when this bit is set,
|
|
/// the modem outputs are also fed through to the modem inputs. This bit
|
|
/// is cleared to 0 on reset, to disable loopback.
|
|
pub enable_loopback: bool,
|
|
/// `TXE` Transmit enable. If this bit is set to 1, the transmit section
|
|
/// of the UART is enabled. Data transmission occurs for either UART
|
|
/// signals, or SIR signals depending on the setting of the SIREN bit.
|
|
/// When the UART is disabled in the middle of transmission, it
|
|
/// completes the current character before stopping.
|
|
pub enable_transmit: bool,
|
|
/// `RXE` Receive enable. If this bit is set to 1, the receive section
|
|
/// of the UART is enabled. Data reception occurs for either UART
|
|
/// signals or SIR signals depending on the setting of the SIREN bit.
|
|
/// When the UART is disabled in the middle of reception, it completes
|
|
/// the current character before stopping.
|
|
pub enable_receive: bool,
|
|
/// `DTR` Data transmit ready. This bit is the complement of the UART
|
|
/// data transmit ready, `nUARTDTR`, modem status output. That is, when
|
|
/// the bit is programmed to a 1 then `nUARTDTR` is LOW.
|
|
pub data_transmit_ready: bool,
|
|
/// `RTS` Request to send. This bit is the complement of the UART
|
|
/// request to send, `nUARTRTS`, modem status output. That is, when the
|
|
/// bit is programmed to a 1 then `nUARTRTS` is LOW.
|
|
pub request_to_send: bool,
|
|
/// `Out1` This bit is the complement of the UART Out1 (`nUARTOut1`)
|
|
/// modem status output. That is, when the bit is programmed to a 1 the
|
|
/// output is 0. For DTE this can be used as Data Carrier Detect (DCD).
|
|
pub out_1: bool,
|
|
/// `Out2` This bit is the complement of the UART Out2 (`nUARTOut2`)
|
|
/// modem status output. That is, when the bit is programmed to a 1, the
|
|
/// output is 0. For DTE this can be used as Ring Indicator (RI).
|
|
pub out_2: bool,
|
|
/// `RTSEn` RTS hardware flow control enable. If this bit is set to 1,
|
|
/// RTS hardware flow control is enabled. Data is only requested when
|
|
/// there is space in the receive FIFO for it to be received.
|
|
pub rts_hardware_flow_control_enable: bool,
|
|
/// `CTSEn` CTS hardware flow control enable. If this bit is set to 1,
|
|
/// CTS hardware flow control is enabled. Data is only transmitted when
|
|
/// the `nUARTCTS` signal is asserted.
|
|
pub cts_hardware_flow_control_enable: bool,
|
|
}
|
|
|
|
impl Control {
|
|
pub fn reset(&mut self) {
|
|
*self = 0.into();
|
|
self.set_enable_receive(true);
|
|
self.set_enable_transmit(true);
|
|
}
|
|
}
|
|
|
|
impl Default for Control {
|
|
fn default() -> Self {
|
|
let mut ret: Self = 0.into();
|
|
ret.reset();
|
|
ret
|
|
}
|
|
}
|
|
|
|
/// Interrupt status bits in UARTRIS, UARTMIS, UARTIMSC
|
|
pub const INT_OE: u32 = 1 << 10;
|
|
pub const INT_BE: u32 = 1 << 9;
|
|
pub const INT_PE: u32 = 1 << 8;
|
|
pub const INT_FE: u32 = 1 << 7;
|
|
pub const INT_RT: u32 = 1 << 6;
|
|
pub const INT_TX: u32 = 1 << 5;
|
|
pub const INT_RX: u32 = 1 << 4;
|
|
pub const INT_DSR: u32 = 1 << 3;
|
|
pub const INT_DCD: u32 = 1 << 2;
|
|
pub const INT_CTS: u32 = 1 << 1;
|
|
pub const INT_RI: u32 = 1 << 0;
|
|
pub const INT_E: u32 = INT_OE | INT_BE | INT_PE | INT_FE;
|
|
pub const INT_MS: u32 = INT_RI | INT_DSR | INT_DCD | INT_CTS;
|
|
|
|
#[repr(u32)]
|
|
pub enum Interrupt {
|
|
OE = 1 << 10,
|
|
BE = 1 << 9,
|
|
PE = 1 << 8,
|
|
FE = 1 << 7,
|
|
RT = 1 << 6,
|
|
TX = 1 << 5,
|
|
RX = 1 << 4,
|
|
DSR = 1 << 3,
|
|
DCD = 1 << 2,
|
|
CTS = 1 << 1,
|
|
RI = 1 << 0,
|
|
}
|
|
|
|
impl Interrupt {
|
|
pub const E: u32 = INT_OE | INT_BE | INT_PE | INT_FE;
|
|
pub const MS: u32 = INT_RI | INT_DSR | INT_DCD | INT_CTS;
|
|
}
|
|
}
|
|
|
|
// TODO: You must disable the UART before any of the control registers are
|
|
// reprogrammed. When the UART is disabled in the middle of transmission or
|
|
// reception, it completes the current character before stopping
|