arm: Remove frq properties on CMSDK timer, dualtimer, watchdog, ARMSSE

Now no users are setting the frq properties on the CMSDK timer,
dualtimer, watchdog or ARMSSE SoC devices, we can remove the
properties and the struct fields that back them.

Signed-off-by: Peter Maydell <peter.maydell@linaro.org>
Reviewed-by: Philippe Mathieu-Daudé <f4bug@amsat.org>
Reviewed-by: Luc Michel <luc@lmichel.fr>
Tested-by: Philippe Mathieu-Daudé <f4bug@amsat.org>
Message-id: 20210128114145.20536-25-peter.maydell@linaro.org
Message-id: 20210121190622.22000-25-peter.maydell@linaro.org
This commit is contained in:
Peter Maydell 2021-01-28 11:41:44 +00:00
parent 911612989d
commit 38867d0b7e
8 changed files with 0 additions and 28 deletions

View file

@ -16,7 +16,6 @@
* https://developer.arm.com/products/system-design/system-design-kits/cortex-m-system-design-kit
*
* QEMU interface:
* + QOM property "pclk-frq": frequency at which the timer is clocked
* + Clock input "TIMCLK": clock (for both timers)
* + sysbus MMIO region 0: the register bank
* + sysbus IRQ 0: combined timer interrupt TIMINTC
@ -63,7 +62,6 @@ struct CMSDKAPBDualTimer {
/*< public >*/
MemoryRegion iomem;
qemu_irq timerintc;
uint32_t pclk_frq;
Clock *timclk;
CMSDKAPBDualTimerModule timermod[CMSDK_APB_DUALTIMER_NUM_MODULES];

View file

@ -23,7 +23,6 @@ OBJECT_DECLARE_SIMPLE_TYPE(CMSDKAPBTimer, CMSDK_APB_TIMER)
/*
* QEMU interface:
* + QOM property "pclk-frq": frequency at which the timer is clocked
* + Clock input "pclk": clock for the timer
* + sysbus MMIO region 0: the register bank
* + sysbus IRQ 0: timer interrupt TIMERINT
@ -35,7 +34,6 @@ struct CMSDKAPBTimer {
/*< public >*/
MemoryRegion iomem;
qemu_irq timerint;
uint32_t pclk_frq;
struct ptimer_state *timer;
Clock *pclk;