mirror of
https://github.com/Motorhead1991/qemu.git
synced 2025-08-05 00:33:55 -06:00
hw/nvme: Add OCP SMART / Health Information Extended Log Page
The Open Compute Project [1] includes a Datacenter NVMe SSD Specification [2]. The most recent version of this specification (as of November 2024) is 2.6.1. This specification layers on top of the NVM Express specifications [3] to provide additional functionality. A key part of of this is the 512 Byte OCP SMART / Health Information Extended log page that is defined in Section 4.8.6 of the specification. We add a controller argument (ocp) that toggles on/off the SMART log extended structure. To accommodate different vendor specific specifications like OCP, we add a multiplexing function (nvme_vendor_specific_log) which will route to the different log functions based on arguments and log ids. We only return the OCP extended SMART log when the command is 0xC0 and ocp has been turned on in the nvme argumants. Though we add the whole nvme SMART log extended structure, we only populate the physical_media_units_{read,written}, log_page_version and log_page_uuid. This patch is based on work done by Joel but has been modified enough that he requested a co-developed-by tag rather than a signed-off-by. [1]: https://www.opencompute.org/ [2]: https://www.opencompute.org/documents/datacenter-nvme-ssd-specification-v2-6-1-pdf [3]: https://nvmexpress.org/specifications/ Signed-off-by: Stephen Bates <sbates@raithlin.com> Co-developed-by: Joel Granados <j.granados@samsung.com> Reviewed-by: Klaus Jensen <k.jensen@samsung.com> Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
This commit is contained in:
parent
b69801dd6b
commit
23a4b3ebc7
4 changed files with 108 additions and 0 deletions
|
@ -53,6 +53,13 @@ parameters.
|
|||
Vendor ID. Set this to ``on`` to revert to the unallocated Intel ID
|
||||
previously used.
|
||||
|
||||
``ocp`` (default: ``off``)
|
||||
The Open Compute Project defines the Datacenter NVMe SSD Specification that
|
||||
sits on top of NVMe. It describes additional commands and NVMe behaviors
|
||||
specific for the Datacenter. When this option is ``on`` OCP features such as
|
||||
the SMART / Health information extended log become available in the
|
||||
controller. We emulate version 5 of this log page.
|
||||
|
||||
Additional Namespaces
|
||||
---------------------
|
||||
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue