mirror of
https://github.com/Motorhead1991/qemu.git
synced 2025-08-08 02:03:56 -06:00
docs: Move pr-manager.rst into the system manual
Move the pr-manager documentation into the system manual. Some of it (the documentation of the pr-manager-helper tool) should be in tools, but we will split it up after moving it. Signed-off-by: Peter Maydell <peter.maydell@linaro.org> Reviewed-by: Alex Bennée <alex.bennee@linaro.org>
This commit is contained in:
parent
e8eee8d3d9
commit
0daf34fd3a
2 changed files with 1 additions and 0 deletions
111
docs/system/pr-manager.rst
Normal file
111
docs/system/pr-manager.rst
Normal file
|
@ -0,0 +1,111 @@
|
|||
======================================
|
||||
Persistent reservation managers
|
||||
======================================
|
||||
|
||||
SCSI persistent Reservations allow restricting access to block devices
|
||||
to specific initiators in a shared storage setup. When implementing
|
||||
clustering of virtual machines, it is a common requirement for virtual
|
||||
machines to send persistent reservation SCSI commands. However,
|
||||
the operating system restricts sending these commands to unprivileged
|
||||
programs because incorrect usage can disrupt regular operation of the
|
||||
storage fabric.
|
||||
|
||||
For this reason, QEMU's SCSI passthrough devices, ``scsi-block``
|
||||
and ``scsi-generic`` (both are only available on Linux) can delegate
|
||||
implementation of persistent reservations to a separate object,
|
||||
the "persistent reservation manager". Only PERSISTENT RESERVE OUT and
|
||||
PERSISTENT RESERVE IN commands are passed to the persistent reservation
|
||||
manager object; other commands are processed by QEMU as usual.
|
||||
|
||||
-----------------------------------------
|
||||
Defining a persistent reservation manager
|
||||
-----------------------------------------
|
||||
|
||||
A persistent reservation manager is an instance of a subclass of the
|
||||
"pr-manager" QOM class.
|
||||
|
||||
Right now only one subclass is defined, ``pr-manager-helper``, which
|
||||
forwards the commands to an external privileged helper program
|
||||
over Unix sockets. The helper program only allows sending persistent
|
||||
reservation commands to devices for which QEMU has a file descriptor,
|
||||
so that QEMU will not be able to effect persistent reservations
|
||||
unless it has access to both the socket and the device.
|
||||
|
||||
``pr-manager-helper`` has a single string property, ``path``, which
|
||||
accepts the path to the helper program's Unix socket. For example,
|
||||
the following command line defines a ``pr-manager-helper`` object and
|
||||
attaches it to a SCSI passthrough device::
|
||||
|
||||
$ qemu-system-x86_64
|
||||
-device virtio-scsi \
|
||||
-object pr-manager-helper,id=helper0,path=/var/run/qemu-pr-helper.sock
|
||||
-drive if=none,id=hd,driver=raw,file.filename=/dev/sdb,file.pr-manager=helper0
|
||||
-device scsi-block,drive=hd
|
||||
|
||||
Alternatively, using ``-blockdev``::
|
||||
|
||||
$ qemu-system-x86_64
|
||||
-device virtio-scsi \
|
||||
-object pr-manager-helper,id=helper0,path=/var/run/qemu-pr-helper.sock
|
||||
-blockdev node-name=hd,driver=raw,file.driver=host_device,file.filename=/dev/sdb,file.pr-manager=helper0
|
||||
-device scsi-block,drive=hd
|
||||
|
||||
----------------------------------
|
||||
Invoking :program:`qemu-pr-helper`
|
||||
----------------------------------
|
||||
|
||||
QEMU provides an implementation of the persistent reservation helper,
|
||||
called :program:`qemu-pr-helper`. The helper should be started as a
|
||||
system service and supports the following option:
|
||||
|
||||
-d, --daemon run in the background
|
||||
-q, --quiet decrease verbosity
|
||||
-v, --verbose increase verbosity
|
||||
-f, --pidfile=path PID file when running as a daemon
|
||||
-k, --socket=path path to the socket
|
||||
-T, --trace=trace-opts tracing options
|
||||
|
||||
By default, the socket and PID file are placed in the runtime state
|
||||
directory, for example :file:`/var/run/qemu-pr-helper.sock` and
|
||||
:file:`/var/run/qemu-pr-helper.pid`. The PID file is not created
|
||||
unless :option:`-d` is passed too.
|
||||
|
||||
:program:`qemu-pr-helper` can also use the systemd socket activation
|
||||
protocol. In this case, the systemd socket unit should specify a
|
||||
Unix stream socket, like this::
|
||||
|
||||
[Socket]
|
||||
ListenStream=/var/run/qemu-pr-helper.sock
|
||||
|
||||
After connecting to the socket, :program:`qemu-pr-helper`` can optionally drop
|
||||
root privileges, except for those capabilities that are needed for
|
||||
its operation. To do this, add the following options:
|
||||
|
||||
-u, --user=user user to drop privileges to
|
||||
-g, --group=group group to drop privileges to
|
||||
|
||||
---------------------------------------------
|
||||
Multipath devices and persistent reservations
|
||||
---------------------------------------------
|
||||
|
||||
Proper support of persistent reservation for multipath devices requires
|
||||
communication with the multipath daemon, so that the reservation is
|
||||
registered and applied when a path is newly discovered or becomes online
|
||||
again. :command:`qemu-pr-helper` can do this if the ``libmpathpersist``
|
||||
library was available on the system at build time.
|
||||
|
||||
As of August 2017, a reservation key must be specified in ``multipath.conf``
|
||||
for ``multipathd`` to check for persistent reservation for newly
|
||||
discovered paths or reinstated paths. The attribute can be added
|
||||
to the ``defaults`` section or the ``multipaths`` section; for example::
|
||||
|
||||
multipaths {
|
||||
multipath {
|
||||
wwid XXXXXXXXXXXXXXXX
|
||||
alias yellow
|
||||
reservation_key 0x123abc
|
||||
}
|
||||
}
|
||||
|
||||
Linking :program:`qemu-pr-helper` to ``libmpathpersist`` does not impede
|
||||
its usage on regular SCSI devices.
|
Loading…