watchdog/diag288: correctly register for system reset requests

The diag288 watchdog is no sysbus device, therefore it doesn't get
triggered on resets automatically using dc->reset.

Let's register the reset handler manually, so we get correctly notified
again when a system reset was requested. Also reset the watchdog on
subsystem resets that don't trigger a full system reset.

Signed-off-by: Xu Wang <gesaint@linux.vnet.ibm.com>
Reviewed-by: David Hildenbrand <dahi@linux.vnet.ibm.com>
Signed-off-by: Cornelia Huck <cornelia.huck@de.ibm.com>
Tested-by: Christian Borntraeger <borntraeger@de.ibm.com>
Reviewed-by: Andreas Färber <afaerber@suse.de>
This commit is contained in:
Xu Wang 2015-06-29 08:21:10 +02:00 committed by Cornelia Huck
parent 0030ff4047
commit 0c7322cfd3
2 changed files with 13 additions and 1 deletions

View file

@ -40,6 +40,13 @@ static void wdt_diag288_reset(DeviceState *dev)
timer_del(diag288->timer);
}
static void diag288_reset(void *opaque)
{
DeviceState *diag288 = opaque;
wdt_diag288_reset(diag288);
}
static void diag288_timer_expired(void *dev)
{
qemu_log_mask(CPU_LOG_RESET, "Watchdog timer expired.\n");
@ -80,6 +87,7 @@ static void wdt_diag288_realize(DeviceState *dev, Error **errp)
{
DIAG288State *diag288 = DIAG288(dev);
qemu_register_reset(diag288_reset, diag288);
diag288->timer = timer_new_ns(QEMU_CLOCK_VIRTUAL, diag288_timer_expired,
dev);
}