docs : make modifications to all md files to make them compatible with mkdocs

all markdown files must have a single H1 heading at the top.

Signed-off-by: Damien Martin <damlobster@gmail.com>

Update CNAME
This commit is contained in:
Damien 2021-07-22 00:40:40 +02:00 committed by KevinOConnor
parent 7e88f9220c
commit cff61605fb
44 changed files with 565 additions and 536 deletions

View file

@ -1,3 +1,5 @@
# Delta calibration
This document describes Klipper's automatic calibration system for
"delta" style printers.
@ -14,8 +16,7 @@ tower endstop switches. If one is using Trinamic stepper motor drivers
then consider enabling [endstop phase](Endstop_Phase.md) detection to
improve the accuracy of those switches.
Automatic vs manual probing
===========================
## Automatic vs manual probing
Klipper supports calibrating the delta parameters via a manual probing
method or via an automatic Z probe.
@ -37,8 +38,7 @@ probes are rarely suitable for use on a delta (because minor effector
tilt will result in a probe location bias). If using the probe anyway,
then be sure to rerun probe calibration after any delta calibration.
Basic delta calibration
=======================
## Basic delta calibration
Klipper has a DELTA_CALIBRATE command that can perform basic delta
calibration. This command probes seven different points on the bed and
@ -84,8 +84,7 @@ accurate enough for basic printing. If this is a new printer, this is
a good time to print some basic objects and verify general
functionality.
Enhanced delta calibration
==========================
## Enhanced delta calibration
The basic delta calibration generally does a good job of calculating
delta parameters such that the nozzle is the correct distance from the
@ -215,8 +214,7 @@ to reenter the raw distance measurements after running SAVE_CONFIG, as
this command changes the printer configuration and the raw
measurements no longer apply.
Additional notes
----------------
### Additional notes
* If the delta printer has good dimensional accuracy then the distance
between any two pillars should be around 74mm and the width of every
@ -236,8 +234,7 @@ Additional notes
arm length may result in a tilt to the effector and some of that
tilt may be accounted for by adjusting the arm length parameters.
Using Bed Mesh on a Delta
=========================
## Using Bed Mesh on a Delta
It is possible to use [bed mesh](Bed_Mesh.md) on a delta. However, it
is important to obtain good delta calibration prior to enabling a bed