@ -190,10 +190,10 @@ The following commands are available when the "delta_calibrate" config
|
|||
section is enabled:
|
||||
- `DELTA_CALIBRATE [METHOD=manual]`: This command will probe seven
|
||||
points on the bed and recommend updated endstop positions, tower
|
||||
angles, and radius.
|
||||
- `NEXT`: If manual bed probing is enabled, then one can use this
|
||||
command to move to the next probing point during a DELTA_CALIBRATE
|
||||
operation.
|
||||
angles, and radius. If METHOD=manual is specified then the manual
|
||||
probing tool is activated - see the MANUAL_PROBE command above for
|
||||
details on the additional commands available while this tool is
|
||||
active.
|
||||
- `DELTA_ANALYZE`: This command is used during enhanced delta
|
||||
calibration. See [Delta Calibrate](Delta_Calibrate.md) for details.
|
||||
|
||||
|
@ -203,10 +203,10 @@ The following commands are available when the "bed_tilt" config
|
|||
section is enabled:
|
||||
- `BED_TILT_CALIBRATE [METHOD=manual]`: This command will probe the
|
||||
points specified in the config and then recommend updated x and y
|
||||
tilt adjustments.
|
||||
- `NEXT`: If manual bed probing is enabled, then one can use this
|
||||
command to move to the next probing point during a
|
||||
BED_TILT_CALIBRATE operation.
|
||||
tilt adjustments. If METHOD=manual is specified then the manual
|
||||
probing tool is activated - see the MANUAL_PROBE command above for
|
||||
details on the additional commands available while this tool is
|
||||
active.
|
||||
|
||||
## Mesh Bed Leveling
|
||||
|
||||
|
@ -215,10 +215,10 @@ section is enabled:
|
|||
- `BED_MESH_CALIBRATE [METHOD=manual]`: This command probes the bed
|
||||
using generated points specified by the parameters in the
|
||||
config. After probing, a mesh is generated and z-movement is
|
||||
adjusted according to the mesh.
|
||||
- `NEXT`: If manual bed probing is enabled, then one can use this
|
||||
command to move to the next probing point during a
|
||||
BED_MESH_CALIBRATE operation.
|
||||
adjusted according to the mesh. If METHOD=manual is specified then
|
||||
the manual probing tool is activated - see the MANUAL_PROBE command
|
||||
above for details on the additional commands available while this
|
||||
tool is active.
|
||||
- `BED_MESH_OUTPUT`: This command outputs the current probed z values
|
||||
and current mesh values to the terminal.
|
||||
- `BED_MESH_MAP`: This command probes the bed in a similar fashion
|
||||
|
|