probe: Use manual_probe helper when performing manual probes

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
Kevin O'Connor 2019-02-09 22:54:24 -05:00
parent 35ea4a137d
commit b0b9fc6f4a
2 changed files with 24 additions and 27 deletions

View file

@ -190,10 +190,10 @@ The following commands are available when the "delta_calibrate" config
section is enabled:
- `DELTA_CALIBRATE [METHOD=manual]`: This command will probe seven
points on the bed and recommend updated endstop positions, tower
angles, and radius.
- `NEXT`: If manual bed probing is enabled, then one can use this
command to move to the next probing point during a DELTA_CALIBRATE
operation.
angles, and radius. If METHOD=manual is specified then the manual
probing tool is activated - see the MANUAL_PROBE command above for
details on the additional commands available while this tool is
active.
- `DELTA_ANALYZE`: This command is used during enhanced delta
calibration. See [Delta Calibrate](Delta_Calibrate.md) for details.
@ -203,10 +203,10 @@ The following commands are available when the "bed_tilt" config
section is enabled:
- `BED_TILT_CALIBRATE [METHOD=manual]`: This command will probe the
points specified in the config and then recommend updated x and y
tilt adjustments.
- `NEXT`: If manual bed probing is enabled, then one can use this
command to move to the next probing point during a
BED_TILT_CALIBRATE operation.
tilt adjustments. If METHOD=manual is specified then the manual
probing tool is activated - see the MANUAL_PROBE command above for
details on the additional commands available while this tool is
active.
## Mesh Bed Leveling
@ -215,10 +215,10 @@ section is enabled:
- `BED_MESH_CALIBRATE [METHOD=manual]`: This command probes the bed
using generated points specified by the parameters in the
config. After probing, a mesh is generated and z-movement is
adjusted according to the mesh.
- `NEXT`: If manual bed probing is enabled, then one can use this
command to move to the next probing point during a
BED_MESH_CALIBRATE operation.
adjusted according to the mesh. If METHOD=manual is specified then
the manual probing tool is activated - see the MANUAL_PROBE command
above for details on the additional commands available while this
tool is active.
- `BED_MESH_OUTPUT`: This command outputs the current probed z values
and current mesh values to the terminal.
- `BED_MESH_MAP`: This command probes the bed in a similar fashion