mirror of
https://github.com/Klipper3d/klipper.git
synced 2025-08-07 14:04:17 -06:00
canbus: Rework CAN command protocol
Rework the micro-controller command protocol so that it supports direct communication with the serialqueue.c code. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
041692828c
commit
6cb419a90a
5 changed files with 162 additions and 74 deletions
65
docs/CANBUS_protocol.md
Normal file
65
docs/CANBUS_protocol.md
Normal file
|
@ -0,0 +1,65 @@
|
|||
This document describes the protocol Klipper uses to communicate over
|
||||
[CAN bus](https://en.wikipedia.org/wiki/CAN_bus).
|
||||
|
||||
# Micro-controller id assignment
|
||||
|
||||
Klipper uses only CAN 2.0A standard size CAN bus packets, which are
|
||||
limited to 8 data bytes and an 11-bit CAN bus identifier. In order to
|
||||
support efficient communication, each micro-controller is assigned at
|
||||
run-time a unique 1-byte CAN bus nodeid (`canbus_nodeid`) for general
|
||||
Klipper command and response traffic. Klipper command messages going
|
||||
from host to micro-controller use the CAN bus id of `canbus_nodeid *
|
||||
2 + 256`, while Klipper response messages from micro-controller to
|
||||
host use `canbus_nodeid * 2 + 256 + 1`.
|
||||
|
||||
Each micro-controller has a factory assigned unique chip identifier
|
||||
that is used during id assignment. This identifier can exceed the
|
||||
length of one CAN packet, so a hash function is used to generate a
|
||||
unique 6-byte id (`canbus_uuid`) from the factory id.
|
||||
|
||||
# Admin messages
|
||||
|
||||
Admin messages are used for id assignment. Admin messages sent from
|
||||
host to micro-controller use the CAN bus id `0x3f0` and messages sent
|
||||
from micro-controller to host use the CAN bus id `0x3f1`. All
|
||||
micro-controllers listen to messages on id `0x3f0`; that id can be
|
||||
thought of as a "broadcast address".
|
||||
|
||||
## CMD_QUERY_UNASSIGNED message
|
||||
|
||||
This command queries all micro-controllers that have not yet been
|
||||
assigned a `canbus_nodeid`. Unassigned micro-controllers will respond
|
||||
with a RESP_NEED_NODEID response message.
|
||||
|
||||
The CMD_QUERY_UNASSIGNED message format is:
|
||||
`<1-byte message_id = 0x00>`
|
||||
|
||||
## CMD_SET_NODEID message
|
||||
|
||||
This command assigns a `canbus_nodeid` to the micro-controller with a
|
||||
given `canbus_uuid`.
|
||||
|
||||
The CMD_SET_NODEID message format is:
|
||||
`<1-byte message_id = 0x01><6-byte canbus_uuid><1-byte canbus_nodeid>`
|
||||
|
||||
## RESP_NEED_NODEID message
|
||||
|
||||
The RESP_NEED_NODEID message format is:
|
||||
`<1-byte message_id = 0x20><6-byte canbus_uuid>`
|
||||
|
||||
# Data Packets
|
||||
|
||||
A micro-controller that has been assigned a nodeid via the
|
||||
CMD_SET_NODEID command can send and receive data packets.
|
||||
|
||||
The packet data in messages using the node's receive CAN bus id
|
||||
(`canbus_nodeid * 2 + 256`) are simply appended to a buffer, and when
|
||||
a complete [mcu protocol message](Protocol.md) is found its contents
|
||||
are parsed and processed. The data is treated as a byte stream - there
|
||||
is no requirement for the start of a Klipper message block to align
|
||||
with the start of a CAN bus packet.
|
||||
|
||||
Similarly, mcu protocol message responses are sent from
|
||||
micro-controller to host by copying the message data into one or more
|
||||
packets with the node's transmit CAN bus id (`canbus_nodeid * 2 +
|
||||
256 + 1`).
|
|
@ -60,6 +60,8 @@ communication with the Klipper developers.
|
|||
control API.
|
||||
- [MCU commands](MCU_Commands.md): A description of low-level commands
|
||||
implemented in the micro-controller software.
|
||||
- [CAN bus protocol](CANBUS_protocol.md): Klipper CAN bus message
|
||||
format.
|
||||
- [Debugging](Debugging.md): Information on how to test and debug
|
||||
Klipper.
|
||||
- [Benchmarks](Benchmarks.md): Information on the Klipper benchmark
|
||||
|
|
Loading…
Add table