mirror of
https://github.com/Klipper3d/klipper.git
synced 2025-08-09 06:45:26 -06:00
docs: add initial temperature_probe documentation
Signed-off-by: Eric Callahan <arksine.code@gmail.com>
This commit is contained in:
parent
bd1dbc8af3
commit
6848843224
3 changed files with 183 additions and 0 deletions
|
@ -1415,3 +1415,39 @@ command will probe the points specified in the config and then make independent
|
|||
adjustments to each Z stepper to compensate for tilt. See the PROBE command for
|
||||
details on the optional probe parameters. The optional `HORIZONTAL_MOVE_Z`
|
||||
value overrides the `horizontal_move_z` option specified in the config file.
|
||||
|
||||
### [temperature_probe]
|
||||
|
||||
The following commands are available when a
|
||||
[temperature_probe config section](Config_Reference.md#temperature_probe)
|
||||
is enabled.
|
||||
|
||||
#### TEMPERATURE_PROBE_CALIBRATE
|
||||
`TEMPERATURE_PROBE_CALIBRATE [PROBE=<probe name>] [TARGET=<value>] [STEP=<value>]`:
|
||||
Initiates probe drift calibration for eddy current based probes. The `TARGET`
|
||||
is a target temperature for the last sample. When the temperature recorded
|
||||
during a sample exceeds the `TARGET` calibration will complete. The `STEP`
|
||||
parameter sets temperature delta (in C) between samples. After a sample has
|
||||
been taken, this delta is used to schedule a call to `TEMPERATURE_PROBE_NEXT`.
|
||||
The default `STEP` is 2.
|
||||
|
||||
#### TEMPERATURE_PROBE_NEXT
|
||||
`TEMPERATURE_PROBE_NEXT`: After calibration has started this command is run to
|
||||
take the next sample. It is automatically scheduled to run when the delta
|
||||
specified by `STEP` has been reached, however its also possible to manually run
|
||||
this command to force a new sample. This command is only available during
|
||||
calibration.
|
||||
|
||||
#### TEMPERATURE_PROBE_COMPLETE:
|
||||
`TEMPERATURE_PROBE_COMPLETE`: Can be used to end calibration and save the
|
||||
current result before the `TARGET` temperature is reached. This command
|
||||
is only available during calibration.
|
||||
|
||||
#### ABORT
|
||||
`ABORT`: Aborts the calibration process, discarding the current results.
|
||||
This command is only available during drift calibration.
|
||||
|
||||
### TEMPERATURE_PROBE_ENABLE
|
||||
`TEMPERATURE_PROBE_ENABLE ENABLE=[0|1]`: Sets temperature drift
|
||||
compensation on or off. If ENABLE is set to 0, drift compensation
|
||||
will be disabled, if set to 1 it is enabled.
|
||||
|
|