mirror of
https://github.com/Klipper3d/klipper.git
synced 2025-08-05 21:14:05 -06:00
spi_temperature: Remove spi_mode parameter
All of the Maxim chips can use SPI mode 1, so no need to configure it. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
70f765f62f
commit
5b124d59f2
3 changed files with 2 additions and 11 deletions
|
@ -32,12 +32,10 @@ class SensorBase:
|
|||
pin = pin_params['pin']
|
||||
# SPI bus configuration
|
||||
spi_oid = mcu.create_oid()
|
||||
spi_mode = config.getint('spi_mode', minval=0, maxval=3)
|
||||
spi_speed = config.getint('spi_speed', minval=0)
|
||||
mcu.add_config_cmd(
|
||||
"config_spi oid=%u bus=%u pin=%s"
|
||||
" mode=%u rate=%u shutdown_msg=" % (
|
||||
spi_oid, 0, pin, spi_mode, spi_speed))
|
||||
"config_spi oid=%u bus=0 pin=%s mode=1 rate=%u shutdown_msg=" % (
|
||||
spi_oid, pin, spi_speed))
|
||||
if config_cmd is not None:
|
||||
config_cmd = "".join("%02x" % b for b in config_cmd)
|
||||
mcu.add_config_cmd("spi_send oid=%u data=%s" % (
|
||||
|
|
Loading…