config: Only document thermistors in example.cfg
Move the common temperature amplifier config descriptions to example-extras.cfg. Also, minor changes to wording of some example-extra.cfg sections. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
parent
1a69f38e6e
commit
43453131ac
2 changed files with 81 additions and 91 deletions
|
@ -151,28 +151,23 @@ heater_pin: ar10
|
|||
# setting may be used to limit the total power output (over extended
|
||||
# periods) to the heater. The default is 1.0.
|
||||
sensor_type: EPCOS 100K B57560G104F
|
||||
# Type of sensor - this may be "EPCOS 100K B57560G104F", "ATC
|
||||
# Semitec 104GT-2", "NTC 100K beta 3950", "Honeywell 100K
|
||||
# 135-104LAG-J01", "NTC 100K MGB18-104F39050L32", "AD595", "PT100
|
||||
# INA826", "MAX6675", "MAX31855", "MAX31856", or "MAX31865".
|
||||
# Additional sensor types may be available - see the
|
||||
# example-extras.cfg file for details. This parameter must be
|
||||
# Type of sensor - common thermistors are "EPCOS 100K B57560G104F",
|
||||
# "ATC Semitec 104GT-2", "NTC 100K beta 3950", "Honeywell 100K
|
||||
# 135-104LAG-J01", and "NTC 100K MGB18-104F39050L32". See the
|
||||
# example-extras.cfg file for other sensors. This parameter must be
|
||||
# provided.
|
||||
sensor_pin: analog13
|
||||
# Analog input pin connected to the sensor. This parameter must be
|
||||
# provided.
|
||||
#pullup_resistor: 4700
|
||||
# The resistance (in ohms) of the pullup attached to the
|
||||
# thermistor. This parameter is only valid when the sensor is a
|
||||
# thermistor. The default is 4700 ohms.
|
||||
# The resistance (in ohms) of the pullup attached to the thermistor.
|
||||
# This parameter is only valid when the sensor is a thermistor. The
|
||||
# default is 4700 ohms.
|
||||
#inline_resistor: 0
|
||||
# The resistance (in ohms) of an extra (not heat varying) resistor
|
||||
# that is placed inline with the thermistor. It is rare to set this.
|
||||
# This parameter is only valid when the sensor is a thermistor. The
|
||||
# default is 0 ohms.
|
||||
#adc_voltage: 5.0
|
||||
# The ADC comparison voltage. This parameter is only valid when the
|
||||
# sensor is an AD595 or "PT100 INA826". The default is 5 volts.
|
||||
#smooth_time: 2.0
|
||||
# A time value (in seconds) over which temperature measurements will
|
||||
# be smoothed to reduce the impact of measurement noise. The default
|
||||
|
|