mirror of
https://github.com/Klipper3d/klipper.git
synced 2026-02-07 16:50:54 -07:00
docs: describe eddy error messages
Signed-off-by: Timofey Titovets <nefelim4ag@gmail.com>
This commit is contained in:
parent
f1bd17d83d
commit
1fc9d81095
1 changed files with 35 additions and 0 deletions
|
|
@ -144,3 +144,38 @@ to perform thermal drift calibration:
|
|||
|
||||
As one may conclude, the calibration process outlined above is more challenging
|
||||
and time consuming than most other procedures. It may require practice and several attempts to achieve an optimal calibration.
|
||||
|
||||
## Errors description
|
||||
|
||||
Possible homing errors and actionables:
|
||||
|
||||
- Sensor error
|
||||
- Check logs for detailed error
|
||||
- Eddy I2C STATUS/DATA error.
|
||||
- Check loose wiring.
|
||||
- Try software I2C/decrease I2C rate
|
||||
- Invalid read data
|
||||
- Same as I2C
|
||||
|
||||
Possible sensor errors and actionables:
|
||||
- Frequency over valid hard range
|
||||
- Check frequency configuration
|
||||
- Hardware fault
|
||||
- Frequency over valid soft range
|
||||
- Check frequency configuration
|
||||
- Conversion Watchdog timeout
|
||||
- Hardware fault
|
||||
|
||||
Amplitude Low/High warning messages can mean:
|
||||
- Sensor close to the bed
|
||||
- Sensor far from the bed
|
||||
- Higher temperature than was at the current calibration
|
||||
- Capacitor missing
|
||||
|
||||
On some sensors, it is not possible to completely avoid amplitude
|
||||
warning indicator.
|
||||
|
||||
You can try to redo the `LDC_CALIBRATE_DRIVE_CURRENT` calibration at work
|
||||
temperature or increase `reg_drive_current` by 1-2 from the calibrated value.
|
||||
|
||||
Generally, it is like an engine check light. It may indicate an issue.
|
||||
|
|
|
|||