docs: Note PROBE_CALIBRATE results invalidated on motion system update

Any hardware change to the hotend or probe, change to the kinematics,
or change to the bed tilt is likely to invalidate the results of
PROBE_CALIBRATE.  Try to warn the user of that.

Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
Kevin O'Connor 2020-10-17 19:36:45 -04:00
parent f8cb1e30eb
commit 1b471b482d
3 changed files with 40 additions and 0 deletions

View file

@ -70,6 +70,21 @@ results to the config file with:
SAVE_CONFIG
```
Note that if a change is made to the printer's motion system, hotend
position, or probe location then it will invalidate the results of
PROBE_CALIBRATE.
If the probe has an X or Y offset and the bed tilt is changed (eg, by
adjusting bed screws, running DELTA_CALIBRATE, running Z_TILT_ADJUST,
running QUAD_GANTRY_LEVEL, or similar) then it will invalidate the
results of PROBE_CALIBRATE. After making any of the above adjustments
it will be necessary to run PROBE_CALIBRATE again.
If the results of PROBE_CALIBRATE are invalidated, then any previous
[bed mesh](Bed_Mesh.md) results that were obtained using the probe are
also invalidated - it will be necessary to rerun BED_MESH_CALIBRATE
after recalibrating the probe.
# Repeatability check