Using layer z to calculate total layer number is not
precision, because for some models with sharp top
layer, the top layer may be empty.
Check the final layer change in final gcode file.
This must be same with total layer number.
Jira: Studio-2123
Signed-off-by: salt.wei <salt.wei@bambulab.com>
Change-Id: I5d001a8bb9548c3fb5f67fda966051ac3bb16502
Merge numerically very close Z values when calculate
total layer number
Signed-off-by: salt.wei <salt.wei@bambulab.com>
Change-Id: I4e60ca69fe5b06b66283d6a763d0b231c3d11b5a
This is fix for jira 2061
Layer height is double and may has small difference, which
influence total layer number when support is enabled.
Should use int data and consider EPSION when calculate total
layer number.
Signed-off-by: salt.wei <salt.wei@bambulab.com>
Change-Id: I1bb6c89f2afd162d2d7e7dcff4a9d6a00b94dab3
For pa-cf, the default setting of cooling is
forcing cooling for all outer wall.
And internal tester found that the slowing down by
layer time does not work for outer wall under
this situation.
This is fix for this issue.
Signed-off-by: salt.wei <salt.wei@bambulab.com>
Change-Id: I05aaa16d246f5ea6dc1ae9808050e1281646e184
* Force using of monotonic infill pattern for internal solid infill to get rid of redundant gap fills.
* Fix an issue "Patterntype for Solid and top layer #134"
Add the option to use non-relative extrusion in printer config screen. Some extruders do not play well with relative extrusion...
Remove reference to multi-extruder
Remove reference to multi-extruder
change g-code comment for M83 relative extrusion
changed comment for M83
Remove commented line of code
In this specific case, we delete the old line of code because it refers to a variable that was deleted from the rest of the code (RELATIVE_E_AXIS)
* fix more colors
* fix more color on Mac
Signed-off-by: SoftFever <103989404+SoftFever@users.noreply.github.com>
* fix new windows issue on Mac
Signed-off-by: SoftFever <103989404+SoftFever@users.noreply.github.com>
#137
* Support more PrusaSlicer variables
Signed-off-by: SoftFever <103989404+SoftFever@users.noreply.github.com>
* enhance compatibility: bed_shape and wipe_start_x
* fix more color
* build deps
* only build for PR
Signed-off-by: SoftFever <softfeverever@gmail.com>
Signed-off-by: SoftFever <103989404+SoftFever@users.noreply.github.com>
Signed-off-by: SoftFever <softfeverever@gmail.com>
This is fix for z hop issue that z hop of
layer change is always spiral list even when set
to normal lift
Signed-off-by: salt.wei <salt.wei@bambulab.com>
Change-Id: I7b235a640b0538bedfe4cef61ca24108c1ba7246
If a travel path goes through an overhang expolygons, and their distance
is shorter than threshold, lift type will be set to SpiralLift.
Signed-off-by: yifan.wu <yifan.wu@bambulab.com>
Change-Id: I345788711755dd8611ecf385818e6052cd8abe9e
allow generate wipe tower when print ByObject if there is only one object
Change-Id: I199e9cab7bd7c963edf58e829c663bb91c12f4f8
(cherry picked from commit 7153c30800022f3afb9811c67f88ba28c9b25d20)
Detour travel is wrong in multi color printing when
current position is unclear.
Don't generate detour travel in this case to avoid
colour mixture.
Signed-off-by: salt.wei <salt.wei@bambulab.com>
Change-Id: I2d24b04d99b8a0b34a46c9f88e522e97cb0fe354
1. flush_multiplier will be apply the the flush volume during slicing
rather than only in auto-calc
2. mark too small flush volume as red instead of a warning dialog
3. do not forbidden flush volume lower than the nozzle volume
4. fix incorrect focus status of text input box in WipeTowerDialog
5. check the minimum flush volume based on flush_multiplier
6. limit the decimal digit to two places
Signed-off-by: yifan.wu <yifan.wu@bambulab.com>
Change-Id: Icdcc50c88ecd9463fb9ce73f996d57c2d9f0187f
(cherry picked from commit 60e01edc511f117b05a8a9b92aaf6fd55325e485)
Add default type to plate bed types.
Signed-off-by: yifan.wu <yifan.wu@bambulab.com>
Change-Id: I26f3a64dba4a19b0d882b828f1ee54c84df1879c
(cherry picked from commit 1ebed465d2b3bcd482dd4ba7a5930b721c79fc13)
For PA-cf material, forcing cooling for all outer
wall and using lower fan speed for infill and inner
wall can get more high strength.
Add this cooling strategy.
When set overhang fan threshold to be 0%, then bridge
and all outer wall will be force to cool with
the overhang fan speed.
Signed-off-by: salt.wei <salt.wei@bambulab.com>
Change-Id: Ideed1ac8690f1eeb68aad760678db76bb4dae8ec
So we can set lower acceleration for outer wall now.
Signed-off-by: salt.wei <salt.wei@bambulab.com>
Change-Id: Ib4728bf16f6c540afca62f423c8aab4c9e0c4d02