mirror of
https://github.com/SoftFever/OrcaSlicer.git
synced 2025-08-06 13:34:05 -06:00
Fixed regression and ambiguity about multiple-value placeholders like [first_layer_temperature_1]. Includes several unit tests covering regression. #1899
This commit is contained in:
parent
913ab54a2b
commit
a4b6075600
3 changed files with 55 additions and 7 deletions
|
@ -1,4 +1,4 @@
|
|||
use Test::More tests => 6;
|
||||
use Test::More tests => 14;
|
||||
use strict;
|
||||
use warnings;
|
||||
|
||||
|
@ -46,7 +46,7 @@ use Slic3r::Test;
|
|||
{
|
||||
my $parser = Slic3r::GCode::PlaceholderParser->new;
|
||||
$parser->apply_config(my $config = Slic3r::Config->new_from_defaults);
|
||||
is $parser->process('[temperature_[foo]]', { foo => '0' }),
|
||||
is $parser->process('[temperature_[foo]]', { foo => '1' }),
|
||||
$config->temperature->[0],
|
||||
"nested config options";
|
||||
}
|
||||
|
@ -67,4 +67,43 @@ use Slic3r::Test;
|
|||
ok $gcode =~ /HEIGHT:$h/, 'region config options are replaced in custom G-code';
|
||||
}
|
||||
|
||||
{
|
||||
my $config = Slic3r::Config->new;
|
||||
$config->set('extruder', 2);
|
||||
$config->set('first_layer_temperature', [200,205]);
|
||||
|
||||
{
|
||||
my $print = Slic3r::Test::init_print('20mm_cube', config => $config);
|
||||
my $gcode = Slic3r::Test::gcode($print);
|
||||
ok $gcode =~ /M104 S205 T1/, 'temperature set correctly for non-zero yet single extruder';
|
||||
ok $gcode !~ /M104 S\d+ T0/, 'unused extruder correctly ignored';
|
||||
}
|
||||
|
||||
$config->set('infill_extruder', 1);
|
||||
{
|
||||
my $print = Slic3r::Test::init_print('20mm_cube', config => $config);
|
||||
my $gcode = Slic3r::Test::gcode($print);
|
||||
ok $gcode =~ /M104 S200 T0/, 'temperature set correctly for first extruder';
|
||||
ok $gcode =~ /M104 S205 T1/, 'temperature set correctly for second extruder';
|
||||
}
|
||||
|
||||
$config->set('start_gcode', qq!
|
||||
;__temp0:[infill_extruder][first_layer_temperature_0]__
|
||||
;__temp1:[first_layer_temperature_1]__
|
||||
;__temp2:[first_layer_temperature_2]__
|
||||
;__temp3:[first_layer_temperature_3]__
|
||||
!);
|
||||
{
|
||||
my $print = Slic3r::Test::init_print('20mm_cube', config => $config);
|
||||
my $gcode = Slic3r::Test::gcode($print);
|
||||
# we use the [infill_extruder] placeholder to make sure this test doesn't
|
||||
# catch a false positive caused by the unparsed start G-code option itself
|
||||
# being embedded in the G-code
|
||||
ok $gcode =~ /temp0:1\[/, 'temperature placeholder for _0 ignored';
|
||||
ok $gcode =~ /temp1:200/, 'temperature placeholder for first extruder correctly populated';
|
||||
ok $gcode =~ /temp2:205/, 'temperature placeholder for second extruder correctly populated';
|
||||
ok $gcode =~ /temp3:200/, 'tempearture placeholder for unused extruder populated with first value';
|
||||
}
|
||||
}
|
||||
|
||||
__END__
|
||||
|
|