Relaxed the requirements on the layer height for the Wipe Tower to

the span of 0.15mm to 0.35mm.
This commit is contained in:
bubnikv 2017-06-08 12:10:34 +02:00
parent fe409a76a6
commit a15e6127cf
2 changed files with 6 additions and 15 deletions

View file

@ -855,17 +855,18 @@ sub _update {
}
if ($config->wipe_tower &&
($config->first_layer_height != 0.2 || ($config->layer_height != 0.15 && $config->layer_height != 0.2))) {
($config->first_layer_height != 0.2 || $config->layer_height < 0.15 || $config->layer_height > 0.35)) {
my $dialog = Wx::MessageDialog->new($self,
"The Wipe Tower currently supports only:\n"
. "- first layer height 0.2mm\n"
. "- layer height 0.15mm or 0.2mm\n"
. "- layer height from 0.15mm to 0.35mm\n"
. "\nShall I adjust those settings in order to enable the Wipe Tower?",
'Wipe Tower', wxICON_WARNING | wxYES | wxNO);
my $new_conf = Slic3r::Config->new;
if ($dialog->ShowModal() == wxID_YES) {
$new_conf->set("first_layer_height", 0.2);
$new_conf->set("layer_height", 0.15) if $config->layer_height != 0.15 && $config->layer_height != 0.2;
$new_conf->set("layer_height", 0.15) if $config->layer_height < 0.15;
$new_conf->set("layer_height", 0.35) if $config->layer_height > 0.35;
} else {
$new_conf->set("wipe_tower", 0);
}