ENH:O1D hot bed temperature no longer checks voltage

jira:[STUDIO-9088]

Change-Id: Ia11154705770919694c58b908b3886fe3feb432a
(cherry picked from commit 7e16329d24c9e31ff5fc99eb74ab4b4b9a5e2b13)
This commit is contained in:
tao wang 2025-01-15 20:37:48 +08:00 committed by Noisyfox
parent d6e86ad7bf
commit 8e78915cd2
3 changed files with 23 additions and 1 deletions

View file

@ -2702,7 +2702,12 @@ void StatusPanel::update_temp_ctrl(MachineObject *obj)
if (!obj) return;
m_tempCtrl_bed->SetCurrTemp((int) obj->bed_temp);
m_tempCtrl_bed->SetMaxTemp(obj->get_bed_temperature_limit());
auto limit = obj->get_bed_temperature_limit();
if (obj->bed_temp_range.size() > 1) {
limit = obj->bed_temp_range[1];
}
m_tempCtrl_bed->SetMaxTemp(limit);
if (obj->nozzle_temp_range.size() >= 2) {
m_tempCtrl_nozzle->SetMinTemp(obj->nozzle_temp_range[0]);
@ -3816,7 +3821,12 @@ void StatusPanel::on_set_bed_temp()
long bed_temp;
if (str.ToLong(&bed_temp) && obj) {
set_hold_count(m_temp_bed_timeout);
int limit = obj->get_bed_temperature_limit();
if (obj->bed_temp_range.size() > 1) {
limit = obj->bed_temp_range[1];
}
if (bed_temp >= limit) {
BOOST_LOG_TRIVIAL(info) << "can not set over limit = " << limit << ", set temp = " << bed_temp;
bed_temp = limit;