mirror of
https://github.com/SoftFever/OrcaSlicer.git
synced 2025-07-13 09:47:58 -06:00
FIX: cali modify for get result
Change-Id: I7017eb186fa629b5d46df1b09bf1021936967689
This commit is contained in:
parent
7fc261e644
commit
8009f8991d
5 changed files with 12 additions and 7 deletions
|
@ -1213,7 +1213,7 @@ void CalibrationWizard::update_print_progress()
|
|||
{
|
||||
request_calib_result();
|
||||
}
|
||||
if (curr_obj->print_status == "FINISH")
|
||||
if (curr_obj->print_status == "FINISH" || curr_obj->print_status == "IDLE")
|
||||
{
|
||||
m_button_abort->Enable(false);
|
||||
m_button_abort->SetBitmap(m_bitmap_abort_disable.bmp());
|
||||
|
|
|
@ -1940,7 +1940,7 @@ int MachineObject::command_start_calibration(bool vibration, bool bed_leveling,
|
|||
}
|
||||
}
|
||||
|
||||
int MachineObject::command_start_pa_calibration(const X1CCalibInfos& pa_data)
|
||||
int MachineObject::command_start_pa_calibration(const X1CCalibInfos &pa_data, bool is_manual)
|
||||
{
|
||||
pa_calib_results.clear();
|
||||
if ((printer_type == "BL-P001" || printer_type == "BL-P002")) {
|
||||
|
@ -1948,6 +1948,7 @@ int MachineObject::command_start_pa_calibration(const X1CCalibInfos& pa_data)
|
|||
j["print"]["command"] = "extrusion_cali";
|
||||
j["print"]["sequence_id"] = std::to_string(MachineObject::m_sequence_id++);
|
||||
j["print"]["nozzle_diameter"] = to_string_nozzle_diameter(pa_data.calib_datas[0].nozzle_diameter);
|
||||
j["print"]["manual"] = is_manual;
|
||||
|
||||
for (int i = 0; i < pa_data.calib_datas.size(); ++i) {
|
||||
j["print"]["filaments"][i]["tray_id"] = pa_data.calib_datas[i].tray_id;
|
||||
|
@ -1973,6 +1974,7 @@ int MachineObject::command_set_pa_calibration(const std::vector<PACalibResult>&
|
|||
j["print"]["nozzle_diameter"] = to_string_nozzle_diameter(pa_calib_values[0].nozzle_diameter);
|
||||
|
||||
for (int i = 0; i < pa_calib_values.size(); ++i) {
|
||||
if (pa_calib_values[i].tray_id >= 0)
|
||||
j["print"]["filaments"][i]["tray_id"] = pa_calib_values[i].tray_id;
|
||||
j["print"]["filaments"][i]["filament_id"] = pa_calib_values[i].filament_id;
|
||||
j["print"]["filaments"][i]["setting_id"] = pa_calib_values[i].setting_id;
|
||||
|
@ -3906,6 +3908,8 @@ int MachineObject::parse_json(std::string payload)
|
|||
else if ((*it)["n_coef"].is_string())
|
||||
pa_calib_result.n_coef = stof((*it)["n_coef"].get<std::string>().c_str());
|
||||
|
||||
pa_calib_result.confidence = (*it)["confidence"].get<int>();
|
||||
|
||||
pa_calib_results.push_back(pa_calib_result);
|
||||
}
|
||||
has_get_pa_calib_result = true;
|
||||
|
|
|
@ -338,6 +338,7 @@ public:
|
|||
std::string name;
|
||||
float k_value;
|
||||
float n_coef;
|
||||
int confidence;
|
||||
};
|
||||
|
||||
struct PACalibIndexInfo
|
||||
|
@ -826,7 +827,7 @@ public:
|
|||
int command_start_calibration(bool vibration, bool bed_leveling, bool xcam_cali);
|
||||
|
||||
// PA calibration
|
||||
int command_start_pa_calibration(const X1CCalibInfos& pa_data);
|
||||
int command_start_pa_calibration(const X1CCalibInfos& pa_data, bool is_manual = false);
|
||||
int command_set_pa_calibration(const std::vector<PACalibResult>& pa_calib_values);
|
||||
int command_delete_pa_calibration(const PACalibIndexInfo& pa_calib);
|
||||
int command_get_pa_calibration_tab(float nozzle_diameter, const std::string &filament_id = "");
|
||||
|
|
|
@ -92,7 +92,7 @@ CalibMode CalibUtils::get_calib_mode_by_name(const std::string &name)
|
|||
return CalibMode::Calib_None;
|
||||
}
|
||||
|
||||
void CalibUtils::calib_PA(const X1CCalibInfos& calib_infos, std::string& error_message)
|
||||
void CalibUtils::calib_PA(const X1CCalibInfos &calib_infos, std::string &error_message, bool is_manual)
|
||||
{
|
||||
DeviceManager *dev = Slic3r::GUI::wxGetApp().getDeviceManager();
|
||||
if (!dev)
|
||||
|
@ -103,7 +103,7 @@ void CalibUtils::calib_PA(const X1CCalibInfos& calib_infos, std::string& error_m
|
|||
return;
|
||||
|
||||
if (calib_infos.calib_datas.size() > 0)
|
||||
obj_->command_start_pa_calibration(calib_infos);
|
||||
obj_->command_start_pa_calibration(calib_infos, is_manual);
|
||||
}
|
||||
|
||||
void CalibUtils::emit_get_PA_calib_results(float nozzle_diameter)
|
||||
|
|
|
@ -30,7 +30,7 @@ public:
|
|||
|
||||
static CalibMode get_calib_mode_by_name(const std::string &name);
|
||||
|
||||
static void calib_PA(const X1CCalibInfos& calib_infos, std::string& error_message);
|
||||
static void calib_PA(const X1CCalibInfos &calib_infos, std::string &error_message, bool is_manual = false);
|
||||
|
||||
static void emit_get_PA_calib_results(float nozzle_diameter);
|
||||
static bool get_PA_calib_results(std::vector<PACalibResult> &pa_calib_results);
|
||||
|
|
Loading…
Add table
Add a link
Reference in a new issue