T1 and M702 C are now evaluated by the time estimator to add the new

"filament_load_time" and "filament_unload_time" values to match
the MK3 MMU2 behavior.

Emitting of the remaining times into the output G-code was made optional
through a new "remaining_times" configuration value, so the firmware
flavors and versions, which do not know the M73 code, will not complain.

Configuration changes:

The wipe tower default position was shifted inwards after the wipe tower
coordinate reference point was changed from the center to the left front
corner.

Added the "filament_load_time" and "filament_unload_time" values
to the MK3 MMU filament profiles.

Enabled "remaining_times" for the MK2.5, MK3 and MK3MMU2 printers.
This commit is contained in:
bubnikv 2018-08-04 17:38:25 +02:00
parent ac2b20b54b
commit 71b1e09af9
11 changed files with 133 additions and 10 deletions

View file

@ -1610,6 +1610,7 @@ void TabPrinter::build()
optgroup = page->new_optgroup(_(L("Firmware")));
optgroup->append_single_option_line("gcode_flavor");
optgroup->append_single_option_line("silent_mode");
optgroup->append_single_option_line("remaining_times");
optgroup->m_on_change = [this, optgroup](t_config_option_key opt_key, boost::any value){
wxTheApp->CallAfter([this, opt_key, value](){