mirror of
https://github.com/MarlinFirmware/Marlin.git
synced 2025-07-14 10:17:49 -06:00
M141 Heated Chamber, Temperature rework (#12201)
This commit is contained in:
parent
44571775bd
commit
645ca7af7a
196 changed files with 2183 additions and 676 deletions
|
@ -112,6 +112,20 @@
|
|||
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Thermal Protection parameters for the heated chamber.
|
||||
*/
|
||||
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
|
||||
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
|
||||
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
|
||||
|
||||
/**
|
||||
* Heated chamber watch settings (M141/M191).
|
||||
*/
|
||||
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
|
||||
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
|
|