Cura/resources/quality/ultimaker3/um3_aa0.4_PLA_Fast_Print.inst.cfg
Ghostkeeper d8a066c1e7
Increment instance container version number instead of just quality_changes
Otherwise when we load that quality_changes file we'll deny it because the instance container version number is wrong.

Contributes to issue CURA-5054.
2018-03-09 16:14:24 +01:00

28 lines
705 B
INI

[general]
version = 3
name = Normal
definition = ultimaker3
[metadata]
setting_version = 4
type = quality
quality_type = fast
weight = -1
material = generic_pla
variant = AA 0.4
[values]
cool_fan_full_at_height = =layer_height_0 + 2 * layer_height
cool_fan_speed_max = =cool_fan_speed
infill_line_width = =round(line_width * 0.42 / 0.35, 2)
machine_nozzle_cool_down_speed = 0.75
machine_nozzle_heat_up_speed = 1.6
material_standby_temperature = 100
prime_tower_enable = False
speed_print = 80
speed_layer_0 = 20
speed_topbottom = =math.ceil(speed_print * 30 / 80)
speed_wall = =math.ceil(speed_print * 40 / 80)
speed_wall_0 = =math.ceil(speed_wall * 30 / 40)
top_bottom_thickness = 1
wall_thickness = 1