mirror of
https://github.com/Ultimaker/Cura.git
synced 2025-08-10 07:15:03 -06:00

The material profiles are sent to UM3 with a manufacturer that's obtained from the printer definition rather than the material definition. The printer definition was 'Ultimaker' rather than 'Ultimaker B.V.' and the printer checked against this. Contributes to issue CURA-4159.
62 lines
2.5 KiB
JSON
62 lines
2.5 KiB
JSON
{
|
|
"id": "ultimaker_original",
|
|
"version": 2,
|
|
"name": "Ultimaker Original",
|
|
"inherits": "ultimaker",
|
|
"metadata": {
|
|
"visible": true,
|
|
"author": "Ultimaker",
|
|
"manufacturer": "Ultimaker B.V.",
|
|
"category": "Ultimaker",
|
|
"weight": 4,
|
|
"file_formats": "text/x-gcode",
|
|
"icon": "icon_ultimaker.png",
|
|
"platform": "ultimaker_platform.stl",
|
|
"has_materials": true,
|
|
"first_start_actions": ["UMOUpgradeSelection", "UMOCheckup", "BedLevel"],
|
|
"supported_actions": ["UMOUpgradeSelection", "UMOCheckup", "BedLevel", "UpgradeFirmware"]
|
|
},
|
|
|
|
"overrides": {
|
|
"machine_name": { "default_value": "Ultimaker Original" },
|
|
"machine_width": {
|
|
"default_value": 205
|
|
},
|
|
"machine_height": {
|
|
"default_value": 200
|
|
},
|
|
"machine_depth": {
|
|
"default_value": 205
|
|
},
|
|
"machine_center_is_zero": {
|
|
"default_value": false
|
|
},
|
|
"machine_nozzle_size": {
|
|
"default_value": 0.4
|
|
},
|
|
"machine_head_with_fans_polygon":
|
|
{
|
|
"default_value": [
|
|
[ -75, 35 ],
|
|
[ -75, -18 ],
|
|
[ 18, 35 ],
|
|
[ 18, -18 ]
|
|
]
|
|
},
|
|
"gantry_height": {
|
|
"default_value": 55
|
|
},
|
|
"machine_use_extruder_offset_to_offset_coords": {
|
|
"default_value": true
|
|
},
|
|
"machine_gcode_flavor": {
|
|
"default_value": "RepRap (Marlin/Sprinter)"
|
|
},
|
|
"machine_start_gcode": {
|
|
"default_value": "G21 ;metric values\nG90 ;absolute positioning\nM82 ;set extruder to absolute mode\nM107 ;start with the fan off\nG28 X0 Y0 ;move X/Y to min endstops\nG28 Z0 ;move Z to min endstops\nG1 Z15.0 F9000 ;move the platform down 15mm\nG92 E0 ;zero the extruded length\nG1 F200 E6 ;extrude 6 mm of feed stock\nG92 E0 ;zero the extruded length again\nG1 F9000\n;Put printing message on LCD screen\nM117 Printing..."
|
|
},
|
|
"machine_end_gcode": {
|
|
"value": "'M104 S0 ;extruder heater off' + ('\\nM140 S0 ;heated bed heater off' if machine_heated_bed else '') + '\\nG91 ;relative positioning\\nG1 E-1 F300 ;retract the filament a bit before lifting the nozzle, to release some of the pressure\\nG1 Z+0.5 E-5 X-20 Y-20 F9000 ;move Z up a bit and retract filament even more\\nG28 X0 Y0 ;move X/Y to min endstops, so the head is out of the way\\nM84 ;steppers off\\nG90 ;absolute positioning'"
|
|
}
|
|
}
|
|
}
|