Cura/resources/quality/ultimaker3/um3_aa0.4_ABS_Fast_Print.inst.cfg
Arjen Hiemstra 30e14478af Replace quality profiles with optimised versions of Ruben's script
With the global quality profiles merged this now works properly.

CURA-2645
2016-10-25 15:40:52 +02:00

23 lines
521 B
INI

[general]
version = 2
name = Fast Print
definition = ultimaker3
[metadata]
type = quality
quality_type = fast
material = generic_abs_ultimaker3_AA_0.4
weight = -1
[values]
cool_min_speed = 7
machine_nozzle_cool_down_speed = 0.85
machine_nozzle_heat_up_speed = 1.5
material_print_temperature = 235
material_standby_temperature = 100
prime_tower_size = 16
speed_print = 60
speed_topbottom = =math.ceil(speed_print * 30 / 60)
speed_wall = =math.ceil(speed_print * 40 / 60)
speed_wall_0 = =math.ceil(speed_wall * 30 / 40)