Commit graph

18 commits

Author SHA1 Message Date
Lipu Fei
2aa985c6de Update all profiles to setting_version 7
CURA-6113
2019-01-17 11:49:26 +01:00
Ghostkeeper
139ab2e0bb
Increment setting_version to 6
Because Cura 4.1 is going to have a version upgrade to change the stack files.

Contributes to issue CURA-5848.
2018-12-27 16:39:05 +01:00
THeijmans
2512800340 Support - Brim interactions
Enable Support - brims and disable 'brim replaces support' for all support materials.
2018-10-19 09:25:13 +02:00
Lipu Fei
b81635ac8e Update setting_version to 5 and add 34 -> 40 upgrade
CURA-5450

Also update setting_version for all qualities and variants.
2018-06-12 10:17:35 +02:00
Lipu Fei
ed390738f4 Update all qualities and variants to version 4 2018-04-05 15:14:15 +02:00
Ghostkeeper
d8a066c1e7
Increment instance container version number instead of just quality_changes
Otherwise when we load that quality_changes file we'll deny it because the instance container version number is wrong.

Contributes to issue CURA-5054.
2018-03-09 16:14:24 +01:00
Lipu Fei
0505b16ffb WIP: Update quality profiles
- Add a new field "variant" in "metadata" section for quality profiles.
  "material" will only contain values such as "generic_abs", and
  "variant" will contain values such as "0.25 mm", "AA 0.4", etc.

- Reformat "metadata" section to have the following order:
   - setting_version
   - type
   - quality_type
   - weight
   - global_quality
   - material
   - variant
2018-02-16 14:20:02 +01:00
Lipu Fei
b6dd87081c Add upgrade script for 3.0 to 3.1
CURA-4451

- Add upgrade script for 3.0. to 3.1
- Upgrade old stack files so they will use "empty_quality" as the
  "Not Supported" quality profile.
- Increase SettingVersion to 4
2017-10-30 12:45:25 +01:00
Lipu Fei
fdf5dc049e Update all containers to setting_version 3
CURA-4270
2017-09-04 15:47:04 +02:00
Ghostkeeper
b08c4cd1dc
Update PVA Verydraft support layer thickness
Apparently 0.6mm layers produced edges that were being pulled along with the nozzle. 0.3mm it is then.
2017-07-26 12:39:43 +02:00
Ghostkeeper
06caedbed8
Update PVA profiles with gradual infill settings
These profiles are optimised by hand.
2017-07-24 09:09:14 +02:00
Lipu Fei
3983da30aa Update setting_version to 2 for qualities
CURA-3975
2017-07-06 14:19:20 +02:00
Jaime van Kessel
e40f60a52b Changed profile names
CURA-3777
2017-05-15 16:52:25 +02:00
Ghostkeeper
f0f8871496
Add setting_version to all profiles
This represents the data version number (as opposed to the format version).

Contributes to issue CURA-3427.
2017-05-12 13:40:54 +02:00
Ghostkeeper
397c2666f0
Optimise profiles for 0.8mm cores
Sample testing confirms that these are equal to their originals. Nylon, PLA and PVA were already optimised, but ABS and CPE weren't. Now all are optimised except some 0.4mm core profiles. I'll see to those next. Note that the filament flow compensation setting is still wrong in these profiles (it was wrong in the original profiles as well).

Contributes to issue CURA-3650.
2017-04-12 15:38:07 +02:00
Jaime van Kessel
0c1829af1e Revert "Upgrade built-in instance containers"
This reverts commit b162be4df8.
2017-03-16 11:15:20 +01:00
Ghostkeeper
b162be4df8
Upgrade built-in instance containers
These are now upgraded to version 3, meaning that they will have to increase their version numbers and remove any start_layers_at_same_position settings they define. None of these profiles define any start_layers_at_same_position so it's just the version number then.

Contributes to issue CURA-3479.
2017-03-10 16:49:57 +01:00
Ghostkeeper
039c1b92de
Add profiles for 0.8mm nozzle sizes 2017-03-09 18:11:06 +01:00