Commit graph

5880 commits

Author SHA1 Message Date
Diego Prado Gesto
d8abf8f470
Merge pull request #4185 from Ultimaker/clear_out_old_gcode
Clear out old gcode
2018-08-03 12:00:21 +02:00
alekseisasin
a67fbc5b89
Merge pull request #4186 from Ultimaker/toolbox_development
Continue scrolling over compatibility charts
2018-08-03 11:57:39 +02:00
Aleksei S
9c8ac6e9ed After switching the Monitor Tab set Null to active output printer
CURA-5612
2018-08-03 11:42:55 +02:00
Ian Paschal
c47de04983 Fix bracket style
Contributes to CURA-5598
2018-08-03 11:41:08 +02:00
Ian Paschal
bcedef3bbe Continue scrolling over compatibility charts
Contributes to CURA-5598
2018-08-03 11:38:42 +02:00
Ian Paschal
1d0e88dc16 Fix typing issue 2018-08-03 11:00:56 +02:00
Ian Paschal
1a050968a5 Clear out old gcode
This way if you move the model, and don't hit prepare again, you can end up exporting the old gcode again thinking its new gcode.
2018-08-03 10:51:01 +02:00
Diego Prado Gesto
1a189ba4f5 Simplify normalization formula. 2018-08-03 09:13:19 +02:00
Lipu Fei
066a00653a Add one more layer to the decision tree 2018-08-02 17:15:34 +02:00
Lipu Fei
a303f394c8 Move VariantType to VariantType.py
Less circular dependencies for imports.
2018-08-02 16:11:55 +02:00
Diego Prado Gesto
c14539d63a Fix the sliders that went out of range when using the arrow keys. 2018-08-02 13:12:01 +02:00
fieldOfView
339987be9d Move hardcoded firmware-file table to definitions 2018-08-02 11:50:28 +02:00
fieldOfView
3ac5342dfc Separate firmware updater from USBPrinterOutputDevice 2018-08-02 11:11:22 +02:00
Lipu Fei
e582886e16
Merge pull request #4170 from Ultimaker/focus_layer_slider
CURA-5613 Set the focus in the upper handle in the layer view
2018-08-01 11:26:30 +02:00
fieldOfView
171220205c Merge branch 'fix_firmware_upload' into feature_firmware_updater 2018-08-01 11:25:42 +02:00
Jack Ha
b8ec1d0fa7 In relative mode, the feedback is still absolute and not relative. CURA-5480 2018-08-01 10:52:31 +02:00
Ian Paschal
56437af4d2 CURA-5613 Don't focus on slider
This way arrow keys are able to rotate the viewport
2018-08-01 10:50:29 +02:00
Diego Prado Gesto
d1b6aa8c37 Set the focus in the upper handle in the layer view instead of in the
text field. That makes it easier to release the focus by clicking in the
main view and use the arrow keys to rotate the view.
2018-08-01 08:33:47 +02:00
fieldOfView
846c55a99d Simplify detection of url-encoded filepatch 2018-07-31 09:47:18 +02:00
Diego Prado Gesto
6694b7ac81 CURA-5541 Change is_enabled field to is_active field to be consistent
with the fields in the PackageManager.
2018-07-27 15:56:29 +02:00
alekseisasin
6232f694c5
Merge pull request #4126 from Ultimaker/CURA-5480_relative_movement_in_stretch_script
CURA-5480 Make stretch script work with relative movements
2018-07-25 14:05:08 +02:00
Aleksei S
fca51ac41f Set relative after getting to line G91 2018-07-25 13:44:58 +02:00
Lipu Fei
006c778d3e
Merge pull request #3855 from jorgegarciadev/master
Fix for detecting USB connection to Malyan M200 and Monoprice Mini
2018-07-24 17:00:43 +02:00
Jaime van Kessel
1cb896904b Fixed missed renames of onFinished keyword 2018-07-24 16:24:28 +02:00
Jaime van Kessel
e89983b171 When dismissing the print window, also reset the "sending_gcode" flag
CL-913
2018-07-24 16:17:53 +02:00
Lipu Fei
952bc54452 Make stretch script work with relative movements
CURA-5480
2018-07-24 15:59:02 +02:00
alekseisasin
41194fceed
Merge pull request #4116 from Ultimaker/fix_filament_change_script
Set negative values to retraction in the filament change script
2018-07-24 13:37:27 +02:00
Ian Paschal
320d73c6e5 Retain 3MF mesh positions
Contributes to CURA-5465

Fixed bug by preventing read jobs for 3mf files from being auto-arranged.

Boyscout changes:
- Fixed typo in `ThreeMFReader.py` (`splitted` → `split`)
- Fixed code style in `CuraApplication.py` (`filename` → `file_name`)
2018-07-24 12:17:53 +02:00
Diego Prado Gesto
296b74b032 Set negative values to retraction in the filament change script.
Fixes #4114
2018-07-24 10:48:52 +02:00
Diego Prado Gesto
a7449ade87 When the number of layers is less than 10, the width of the TextField
that shows the layer number in the LayerView is too small, so this
commit adjusts the size.
2018-07-19 11:42:42 +02:00
Ian Paschal
29d1de03d1
Merge pull request #4088 from Ultimaker/CURA-5510_generic_materials_in_toolbox
Add generic material packages to materials page
2018-07-17 14:11:06 +02:00
Diego Prado Gesto
f1379135e0 CURA-5510 Add the Generic materials to the list of the bundled packages
so that they show up as installed.

Show the installed icon on those packages as well.
2018-07-17 13:49:17 +02:00
fieldOfView
65ada30c9c Fix flashing "default" firmware
The url is not QUrl encoded if the "default" firmware is flashed
2018-07-17 09:01:06 +02:00
Ian Paschal
0bde1487e7 Add generic material packages to materials page
Contributes to CURA-5510
2018-07-16 16:13:43 +02:00
Lipu Fei
5ba3beb104
Merge pull request #4084 from Ultimaker/add_cartesio_variants
CURA-5578 Change the Cartesio variants to use the new ones
2018-07-16 15:55:11 +02:00
Jack Ha
4167f81e3b Fix printer missing from the list after connection; now always adds the field 'hidden' in the metadata, don't know why it worked before. CURA-5574 2018-07-16 13:32:35 +02:00
Diego Prado Gesto
5ef8aa09f8 Translate the old material types to the new in the Version Upgrade. 2018-07-16 13:05:32 +02:00
Lipu Fei
9856ccf700
Merge pull request #4073 from Ultimaker/CURA-5572_fix_gcode_reader
CURA-5572 Update the scene when a Gcode is loaded.
2018-07-16 08:07:02 +02:00
Lipu Fei
92da6e0ce3
Merge pull request #4072 from Ultimaker/CURA-5536_installed_check
CURA-5536 Use an icon indicating when a package is installed
2018-07-16 08:05:00 +02:00
Aleksei S
817a304ed1 After reconecting to another port update job status '_is_cancelled' to false
CURA-5549
2018-07-13 23:50:02 +02:00
Diego Prado Gesto
01a26b0360 CURA-5572 The scene was not updated when a Gcode was loaded.
This fixes a bug that we introduced when fixing code style. This was a
bad translation.
2018-07-13 16:05:13 +02:00
Diego Prado Gesto
af697c6999 CURA-5536 The api call does not return the package_count for the showcase, so we can't trust in that value. The total number of material packages by author is now calculated. 2018-07-13 15:13:38 +02:00
Diego Prado Gesto
a8727d7b39 Merge branch 'master' into CURA-5536_installed_check 2018-07-13 14:43:29 +02:00
Diego Prado Gesto
dd7168e8b8 CURA-5536 Add the installed check also to the featured items. 2018-07-13 13:41:19 +02:00
Diego Prado Gesto
62b1d361fa CURA-5536 Set different colors indicating that all the inner packages
are installed of just some.
2018-07-13 13:21:38 +02:00
Diego Prado Gesto
96cc1be2ff CURA-5536 Calculate the number of installed packages by author. 2018-07-13 13:20:56 +02:00
Diego Prado Gesto
1b6c172e6d CURA-5536 Add the icon indicating when a plugin is already installed. 2018-07-13 13:20:32 +02:00
Lipu Fei
49bd249819 Update text for USB printing exit confirmation
CURA-5384
2018-07-13 11:10:15 +02:00
Lipu Fei
c0b7e40b0d Add on-exit callback management and check for active USB printing
CURA-5384
2018-07-13 09:16:11 +02:00
Lipu Fei
ac3d3bc5c0 Revert "Added signal to prevent window closing if USB printer is printing"
This reverts commit 596a7b7169.
2018-07-13 08:08:56 +02:00