reduced printing temperature for BAM 0.1mm layer height profile causes extrusion issues. No drawback for increasing to the default printing temperature are found. PP-190
Overwhelmingly in our community it seems that the overhang and seam quality is better when printing inside-out.
Ultimaker found that the quality is better (in particular the dimensional accuracy) when printing outside-in. So let them have it outside-in and the rest inside-out.
Made after experimental evidence on Reddit (and in the past on Github).
Setting this value smaller could cause scarring when the nozzle offset calibration is not performed. A higher value causes a too big gap between the model and support, resulting in support not being attached to the model on sloped surfaces. PP-185
A bigger horizontal expansion is improving the stability of the support structure. Setting the Support Horizontal Expansion > Support X/Y distance causes the support folding around the object, making it way harder to remove and introducing a lot of additional stringing. PP-185
PVA is stringing a lot due to the too small retract distance. This oozed material is causing under extrusion elsewhere, reducing the strength of the support. Too long retractions could cause reliability issues as well. However, since we reduced the number of retractions by ~40% for the smaller models (for bigger models it is ~0%, but then it is also not relevant since a lot of material is printed in between) with the new settings of PP-108 increasing the retract distance to 6.5mm is safe. PP-185
It's the same hack that we already use for the other instances where we use the tableModel.
For some reason it wasn't done here, so we also had the not updating bug
CURA-9270
That way, an extruder profile can say that they want this.
If any extruder needs this setting enabled, it will be enabled for the whole print.
Done as a 5 minute fix.
The reason for this is that hovering the mouse between the checkbox and text was causing some strange behaviour where sometimes the tooltip would not appear.
The effect of the changes in RecommendedSupportSelector.qml are the same as RecommendedAdhesionSelector.qml. It just required a bit of refactoring to have the checkbox and the textlabel in the same component.
CURA-8849
Removed alwaysRunToEnd on animation since we would like the previous animation to stop if a user clicks through multiple intents triggering multiple animations.
CURA-8849
I tried updating when the qualities change but this was updating before this line
if(recommendedResolutionSelector._previousResolution !== Cura.MachineManager.activeQualityType)
which caused this always to resolve as true
The solution was to update _previousResolution after we select an item in the drop down.
CURA-8849