Since the setting version 18 is used in the arachne beta build, we decided to make the the setting version to 19 in the normal releases, so that we make sure that projects made in arachne beta won't use any version upgrade scripts if a user attempts to open them in 4.12.
CURA-8510
We now have version 18, where Flsun Super Racer has customised profiles.
Nothing changes in the built-in profiles. It only needs a change in the machine instances.
Contributes to issue CURA-8510.
We have a change now that requires a version upgrade. This triggers all profiles to update for the user, and we must update accordingly in the built-in profiles.
Contributes to issue CURA-7118.
This is necessary because our ContainerTree class can only create one tree per definition. This tree is not created separately for every added printer and as such the tree can't be different for every added printer.
However the Ultimaker 2 Olsson block upgrade allows selecting extra variants for the UM2. This changes the available variants in the container tree, so this would be impossible.
By making it a separate definition, it now gets a separate tree. However this does mean that we need to do a version upgrade for this as well.
Contributes to issue CURA-6775.
2019-09-16 14:57:45 +02:00
Renamed from resources/variants/ultimaker2_0.6.inst.cfg (Browse further)