Conflicts:
plugins/SimulationView/SimulationPass.py -> Reverted layer view optimisation in Master while some whitespace changed in Arachne.
resources/definitions -> Bunch of conflicts with profile updates.
resources/quality -> Bunch of conflicts with profile updates.
resources/texts/change_log.txt -> Removed the Arachne change log (as they are internal versions). It'll have to be re-added when we release this version as stable.
Since the setting version 18 is used in the arachne beta build, we decided to make the the setting version to 19 in the normal releases, so that we make sure that projects made in arachne beta won't use any version upgrade scripts if a user attempts to open them in 4.12.
CURA-8510
We now have version 18, where Flsun Super Racer has customised profiles.
Nothing changes in the built-in profiles. It only needs a change in the machine instances.
Contributes to issue CURA-8510.
Although it is not entirely sure yet, we are fairly certain that libArachne release will have
a setting version of 18, so it is changed by this commit. With this change, the VersionUpgrader
will be properly triggered.
Contributes to CURA-7683 and CURA-7656
We have a change now that requires a version upgrade. This triggers all profiles to update for the user, and we must update accordingly in the built-in profiles.
Contributes to issue CURA-7118.
Also convert the values for prime_tower_min_volume to make it behave similar to what the minimum volume used to be. This feature fixed a bug with the computation from volume to thickness. Now it's correct but we have to correct the old values to be still the same (approximately) as what used to be the end result.
Contributes to issue CURA-5457.
- Add a new field "variant" in "metadata" section for quality profiles.
"material" will only contain values such as "generic_abs", and
"variant" will contain values such as "0.25 mm", "AA 0.4", etc.
- Reformat "metadata" section to have the following order:
- setting_version
- type
- quality_type
- weight
- global_quality
- material
- variant
CURA-4451
- Add upgrade script for 3.0. to 3.1
- Upgrade old stack files so they will use "empty_quality" as the
"Not Supported" quality profile.
- Increase SettingVersion to 4
And then also update the profiles to make the profiles end up at what it was originally (I confirmed this with the materials team).
Contributes to issue CURA-3960.
The stand-by temperature in the material profiles is the temperature at which the build plate levelling should be done. The actual stand-by temperature in Cura should be 100, so these profiles have to overwrite the material profile then.
Contributes to issue CURA-3960.
This removes all settings that are equal to the defaults. Some settings are 'common' between all profiles of the same material. I've let those settings bubble up to the material profiles but that change is then obviously only apparent in the fdm_materials repository.
Contributes to issue CURA-3960.