Bind default pre-heat temperature to current build plate temperature
Currently the setting 'resets' when you go out of the print monitor mode. That wasn't the original intention but it works kind of nicely. We'll bring it up in a meeting whether this needs to be changed. Contributes to issue CURA-3161.
This commit is contained in:
parent
78fed0531d
commit
b1a8b28e87
1 changed files with 14 additions and 9 deletions
|
@ -236,12 +236,12 @@ Column
|
|||
anchors.right: parent.right
|
||||
anchors.verticalCenter: parent.verticalCenter
|
||||
|
||||
text: "60" //TODO: Bind this to the default.
|
||||
/*Binding
|
||||
Binding
|
||||
{
|
||||
target: preheatTemperatureInput
|
||||
property: "text"
|
||||
value: {
|
||||
value:
|
||||
{
|
||||
// Stacklevels
|
||||
// 0: user -> unsaved change
|
||||
// 1: quality changes -> saved change
|
||||
|
@ -250,17 +250,20 @@ Column
|
|||
// 4: variant
|
||||
// 5: machine_changes
|
||||
// 6: machine
|
||||
if ((base.resolve != "None" && base.resolve) && (stackLevel != 0) && (stackLevel != 1)) {
|
||||
if ((bedTemperature.resolve != "None" && bedTemperature.resolve) && (bedTemperature.stackLevels[0] != 0) && (bedTemperature.stackLevels[0] != 1))
|
||||
{
|
||||
// We have a resolve function. Indicates that the setting is not settable per extruder and that
|
||||
// we have to choose between the resolved value (default) and the global value
|
||||
// (if user has explicitly set this).
|
||||
return base.resolve;
|
||||
} else {
|
||||
return propertyProvider.properties.value;
|
||||
return bedTemperature.resolve;
|
||||
}
|
||||
else
|
||||
{
|
||||
return bedTemperature.properties.value;
|
||||
}
|
||||
}
|
||||
when: !preheatTemperatureInput.activeFocus
|
||||
}*/
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
@ -270,8 +273,10 @@ Column
|
|||
id: bedTemperature
|
||||
containerStackId: Cura.MachineManager.activeMachineId
|
||||
key: "material_bed_temperature"
|
||||
watchedProperties: ["value", "minimum_value", "maximum_value", "minimum_value_warning", "maximum_value_warning"]
|
||||
watchedProperties: ["value", "minimum_value", "maximum_value", "minimum_value_warning", "maximum_value_warning", "resolve"]
|
||||
storeIndex: 0
|
||||
|
||||
property var resolve: Cura.MachineManager.activeStackId != Cura.MachineManager.activeMachineId ? properties.resolve : "None"
|
||||
}
|
||||
|
||||