@ -20,12 +20,10 @@
|
|||
"overrides": {
|
||||
"machine_name": { "default_value": "Ultimaker 2" },
|
||||
"machine_start_gcode" : {
|
||||
"default_value": "",
|
||||
"value": "\"\" if machine_gcode_flavor == \"UltiGCode\" else \"G21 ;metric values\\nG90 ;absolute positioning\\nM82 ;set extruder to absolute mode\\nM107 ;start with the fan off\\nG28 Z0 ;move Z to bottom endstops\\nG28 X0 Y0 ;move X/Y to endstops\\nG1 X15 Y0 F4000 ;move X/Y to front of printer\\nG1 Z15.0 F9000 ;move the platform to 15mm\\nG92 E0 ;zero the extruded length\\nG1 F200 E10 ;extrude 10 mm of feed stock\\nG92 E0 ;zero the extruded length again\\nG1 F9000\\n;Put printing message on LCD screen\\nM117 Printing...\""
|
||||
},
|
||||
"machine_end_gcode" : {
|
||||
"default_value": "",
|
||||
"value": "\"\" if machine_gcode_flavor == \"UltiGCode\" else \"M104 S0 ;extruder heater off\\nM140 S0 ;heated bed heater off (if you have it)\\nG91 ;relative positioning\\nG1 E-1 F300 ;retract the filament a bit before lifting the nozzle, to release some of the pressure\\nG1 Z+0.5 E-5 X-20 Y-20 F9000 ;move Z up a bit and retract filament even more\\nG28 X0 Y0 ;move X/Y to min endstops, so the head is out of the way\\nM84 ;steppers off\\nG90 ;absolute positioning\""
|
||||
"value": "\";Version _2.6 of the firmware can abort the print too early if the file ends\\n;too soon. However if the file hasn't ended yet because there are comments at\\n;the end of the file, it won't abort yet. Therefore we have to put at least 512\\n;bytes at the end of the g-code so that the file is not yet finished by the\\n;time that the motion planner gets flushed. With firmware version _3.3 this\\n;should be fixed, so this comment wouldn't be necessary any more. Now we have\\n;to pad this text to make precisely 512 bytes.\" if machine_gcode_flavor == \"UltiGCode\" else \"M104 S0 ;extruder heater off\\nM140 S0 ;heated bed heater off (if you have it)\\nG91 ;relative positioning\\nG1 E-1 F300 ;retract the filament a bit before lifting the nozzle, to release some of the pressure\\nG1 Z+0.5 E-5 X-20 Y-20 F9000 ;move Z up a bit and retract filament even more\\nG28 X0 Y0 ;move X/Y to min endstops, so the head is out of the way\\nM84 ;steppers off\\nG90 ;absolute positioning\\n;Version _2.6 of the firmware can abort the print too early if the file ends\\n;too soon. However if the file hasn't ended yet because there are comments at\\n;the end of the file, it won't abort yet. Therefore we have to put at least 512\\n;bytes at the end of the g-code so that the file is not yet finished by the\\n;time that the motion planner gets flushed. With firmware version _3.3 this\\n;should be fixed, so this comment wouldn't be necessary any more. Now we have\\n;to pad this text to make precisely 512 bytes.\""
|
||||
},
|
||||
"machine_width": {
|
||||
"default_value": 223
|
||||
|
|