mirror of
https://github.com/Ultimaker/Cura.git
synced 2025-08-08 22:35:03 -06:00
Merge pull request #4298 from Ultimaker/CURA-5675-reset_machines_for_removed_quality_changes
CURA-5675 Reset machines that use a removed quality changes
This commit is contained in:
commit
9bd51d15ae
1 changed files with 12 additions and 1 deletions
|
@ -363,8 +363,19 @@ class QualityManager(QObject):
|
|||
@pyqtSlot(QObject)
|
||||
def removeQualityChangesGroup(self, quality_changes_group: "QualityChangesGroup"):
|
||||
Logger.log("i", "Removing quality changes group [%s]", quality_changes_group.name)
|
||||
removed_quality_changes_ids = set()
|
||||
for node in quality_changes_group.getAllNodes():
|
||||
self._container_registry.removeContainer(node.getMetaDataEntry("id"))
|
||||
container_id = node.getMetaDataEntry("id")
|
||||
self._container_registry.removeContainer(container_id)
|
||||
removed_quality_changes_ids.add(container_id)
|
||||
|
||||
# Reset all machines that have activated this quality changes to empty.
|
||||
for global_stack in self._container_registry.findContainerStacks(type = "machine"):
|
||||
if global_stack.qualityChanges.getId() in removed_quality_changes_ids:
|
||||
global_stack.qualityChanges = self._empty_quality_changes_container
|
||||
for extruder_stack in self._container_registry.findContainerStacks(type = "extruder_train"):
|
||||
if extruder_stack.qualityChanges.getId() in removed_quality_changes_ids:
|
||||
extruder_stack.qualityChanges = self._empty_quality_changes_container
|
||||
|
||||
#
|
||||
# Rename a set of quality changes containers. Returns the new name.
|
||||
|
|