Give warning when build plate temperature is below volume temperature

It's not going to become lower than the ambient temperature after all.
This commit is contained in:
Ghostkeeper 2019-08-22 13:37:30 +02:00
parent 9f16973215
commit 7ccf46124f
No known key found for this signature in database
GPG key ID: 86BEF881AE2CF276

View file

@ -2200,7 +2200,7 @@
"resolve": "max(extruderValues('default_material_bed_temperature'))",
"default_value": 60,
"minimum_value": "-273.15",
"minimum_value_warning": "0",
"minimum_value_warning": "build_volume_temperature",
"maximum_value_warning": "130",
"enabled": false,
"settable_per_mesh": false,
@ -2217,7 +2217,7 @@
"value": "default_material_bed_temperature",
"resolve": "max(extruderValues('material_bed_temperature'))",
"minimum_value": "-273.15",
"minimum_value_warning": "0",
"minimum_value_warning": "build_volume_temperature",
"maximum_value_warning": "130",
"enabled": "machine_heated_bed and machine_gcode_flavor != \"UltiGCode\"",
"settable_per_mesh": false,
@ -2234,7 +2234,7 @@
"default_value": 60,
"value": "resolveOrValue('material_bed_temperature')",
"minimum_value": "-273.15",
"minimum_value_warning": "max(extruderValues('material_bed_temperature'))",
"minimum_value_warning": "max(build_volume_temperature, max(extruderValues('material_bed_temperature')))",
"maximum_value_warning": "130",
"enabled": "machine_heated_bed and machine_gcode_flavor != \"UltiGCode\"",
"settable_per_mesh": false,