@ -6126,6 +6126,18 @@
"minimum_value_warning": "0.01",
"maximum_value_warning": "0.3",
"settable_per_mesh": true
},
"meshfix_maximum_extrusion_area_deviation":
{
"label": "Maximum Extrusion Area Deviation",
"description": "The maximum extrusion area deviation allowed when removing intermediate points from a straight line. An intermediate point may serve as width-changing point in a long straight line. Therefore, if it is removed, it will cause the line to have a uniform width and, as a result, lose (or gain) a bit of extrusion area. If you increase this you may notice slight under- (or over-) extrusion in between straight parallel walls, as more intermediate width-changing points will be allowed to be removed. Your print will be less accurate, but the g-code will be smaller.",
"type": "float",
"unit": "μm²",
"default_value": 2000,
"minimum_value": "0",
"minimum_value_warning": "500",
"maximum_value_warning": "5000",
"settable_per_mesh": true
}
}
},