Simplifying mp_mini_delta.def.json

Removing minimum/maximum nozzle size, minimum layer_height, and minimum layer_height_0.
This commit is contained in:
PurpleHullPeas 2020-04-04 23:22:17 -05:00 committed by GitHub
parent a1a7d48e46
commit 3cc6b0cb9a
No known key found for this signature in database
GPG key ID: 4AEE18F83AFDEB23

View file

@ -1,22 +1,22 @@
{
"version": 2,
"version": 2,
"name": "MP Mini Delta",
"inherits": "fdmprinter",
"inherits": "fdmprinter",
"metadata": {
"author": "MPMD Facebook Group",
"manufacturer": "Monoprice",
"category": "Other",
"category": "Other",
"file_formats": "text/x-gcode",
"platform": "mp_mini_delta_platform.stl",
"platform": "mp_mini_delta_platform.stl",
"supports_usb_connection": true,
"has_machine_quality": false,
"visible": true,
"platform_offset": [0, 0, 0],
"has_materials": true,
"has_variants": false,
"has_machine_materials": false,
"has_variant_materials": false,
"preferred_quality_type": "normal",
"platform_offset": [0, 0, 0],
"has_materials": true,
"has_variants": false,
"has_machine_materials": false,
"has_variant_materials": false,
"preferred_quality_type": "normal",
"machine_extruder_trains":
{
"0": "mp_mini_delta_extruder_0"
@ -24,14 +24,14 @@
},
"overrides": {
"machine_start_gcode":
{
"default_value": ";MPMD Basic Calibration Tutorial: \n; https://www.thingiverse.com/thing:3892011 \n; \n; If you want to put calibration values in your \n; Start Gcode, put them here. \n; \n;If on stock firmware, at minimum, consider adding \n;M665 R here since there is a firmware bug. \n; \n; Calibration part ends here \n; \nG90 ; switch to absolute positioning \nG92 E0 ; reset extrusion distance \nG1 E20 F200 ; purge 20mm of filament to prime nozzle. \nG92 E0 ; reset extrusion distance \nG4 S5 ; Pause for 5 seconds to allow time for removing extruded filament \nG28 ; start from home position \nG1 E-6 F900 ; retract 6mm of filament before starting the bed leveling process \nG92 E0 ; reset extrusion distance \nG4 S5 ; pause for 5 seconds to allow time for removing extruded filament \nG29 P2 Z0.28 ; Auto-level ; ADJUST Z higher or lower to set first layer height. Start with 0.02 adjustments. \nG1 Z30 ; raise Z 30mm to prepare for priming the nozzle \nG1 E5 F200 ; extrude 5mm of filament to help prime the nozzle just prior to the start of the print \nG92 E0 ; reset extrusion distance \nG4 S5 ; pause for 5 seconds to allow time for cleaning the nozzle and build plate if needed "
},
"machine_end_gcode":
{
"default_value": "M107; \nM104 S0; turn off hotend heater \nM140 S0; turn off bed heater \nG91; Switch to use Relative Coordinates \nG1 E-2 F300; retract the filament a bit before lifting the nozzle to release some of the pressure \nG1 Z5 E-5 F4800; move nozzle up a bit and retract filament even more \nG28 X0; return to home positions so the nozzle is out of the way \nM84; turn off stepper motors \nG90; switch to absolute positioning \nM82; absolute extrusion mode"
},
"machine_start_gcode":
{
"default_value": ";MPMD Basic Calibration Tutorial: \n; https://www.thingiverse.com/thing:3892011 \n; \n; If you want to put calibration values in your \n; Start Gcode, put them here. \n; \n;If on stock firmware, at minimum, consider adding \n;M665 R here since there is a firmware bug. \n; \n; Calibration part ends here \n; \nG90 ; switch to absolute positioning \nG92 E0 ; reset extrusion distance \nG1 E20 F200 ; purge 20mm of filament to prime nozzle. \nG92 E0 ; reset extrusion distance \nG4 S5 ; Pause for 5 seconds to allow time for removing extruded filament \nG28 ; start from home position \nG1 E-6 F900 ; retract 6mm of filament before starting the bed leveling process \nG92 E0 ; reset extrusion distance \nG4 S5 ; pause for 5 seconds to allow time for removing extruded filament \nG29 P2 Z0.28 ; Auto-level ; ADJUST Z higher or lower to set first layer height. Start with 0.02 adjustments. \nG1 Z30 ; raise Z 30mm to prepare for priming the nozzle \nG1 E5 F200 ; extrude 5mm of filament to help prime the nozzle just prior to the start of the print \nG92 E0 ; reset extrusion distance \nG4 S5 ; pause for 5 seconds to allow time for cleaning the nozzle and build plate if needed "
},
"machine_end_gcode":
{
"default_value": "M107; \nM104 S0; turn off hotend heater \nM140 S0; turn off bed heater \nG91; Switch to use Relative Coordinates \nG1 E-2 F300; retract the filament a bit before lifting the nozzle to release some of the pressure \nG1 Z5 E-5 F4800; move nozzle up a bit and retract filament even more \nG28 X0; return to home positions so the nozzle is out of the way \nM84; turn off stepper motors \nG90; switch to absolute positioning \nM82; absolute extrusion mode"
},
"machine_width": { "default_value": 110 },
"machine_depth": { "default_value": 110 },
"machine_height": { "default_value": 120 },
@ -39,17 +39,13 @@
"machine_shape": { "default_value": "elliptic" },
"machine_center_is_zero": { "default_value": true },
"machine_nozzle_size": {
"default_value": 0.4,
"minimum_value": 0.10,
"maximum_value": 0.80
"default_value": 0.4
},
"layer_height": {
"default_value": 0.14,
"minimum_value": 0.04
"default_value": 0.14
},
"layer_height_0": {
"default_value": 0.21,
"minimum_value": 0.07
"layer_height_0": {
"default_value": 0.21
},
"material_bed_temperature": { "value": 40 },
"line_width": { "value": "round(machine_nozzle_size * 0.875, 2)" },