Fix default value min_skin_width_for_expansion.
At some point max_skin_angle_for_expansion s deafult value was updated, but the default value for its child, min_skin_width_for_expansion wasn't altered to reflect that. Fixes #7925
This commit is contained in:
parent
6d7d7bdb95
commit
29e68fe407
1 changed files with 1 additions and 1 deletions
|
@ -2082,7 +2082,7 @@
|
|||
"description": "Skin areas narrower than this are not expanded. This avoids expanding the narrow skin areas that are created when the model surface has a slope close to the vertical.",
|
||||
"unit": "mm",
|
||||
"type": "float",
|
||||
"default_value": 2.24,
|
||||
"default_value": 0,
|
||||
"value": "top_layers * layer_height / math.tan(math.radians(max_skin_angle_for_expansion))",
|
||||
"minimum_value": "0",
|
||||
"enabled": "(top_layers > 0 or bottom_layers > 0) and (top_skin_expand_distance > 0 or bottom_skin_expand_distance > 0)",
|
||||
|
|