Disable Small Skin Area feature for now :-/
We're not sure why this introduces a boatload of small segments into the infill, and we're out of time to try and fix this before the beta. Re-introducing after the beta seems like a bad idea, so this'll have to wait until 5.5 unfortunately. Done as part of fixing for CURA-10500, but for the original Small Skin Area feature, see CURA-10201. For the ticket to (fix? and) reintroduce the feature, see CURA-10670.
This commit is contained in:
parent
2d7f968932
commit
1f7c11667f
1 changed files with 5 additions and 4 deletions
|
@ -1665,15 +1665,16 @@
|
|||
{
|
||||
"label": "Small Top/Bottom Width",
|
||||
"description": "Small top/bottom regions are filled with walls instead of the default top/bottom pattern. This helps to avoids jerky motions.",
|
||||
"value": "skin_line_width * 2",
|
||||
"default_value": 1,
|
||||
"value": "0",
|
||||
"default_value": 0,
|
||||
"minimum_value": "0",
|
||||
"maximum_value_warning": "skin_line_width * 10",
|
||||
"type": "float",
|
||||
"enabled": "(top_layers > 0 or bottom_layers > 0) and top_bottom_pattern != 'concentric'",
|
||||
"enabled": false,
|
||||
"limit_to_extruder": "top_bottom_extruder_nr",
|
||||
"settable_per_mesh": true,
|
||||
"unit": "mm"
|
||||
"unit": "mm",
|
||||
"comment": "Disabled for 5.4.x, as we're worried about micro-segments in the infill. Also disabled in the engine, so forcing this > 0 will not do anything at the moment."
|
||||
},
|
||||
"skin_no_small_gaps_heuristic":
|
||||
{
|
||||
|
|