🐛 Reduce CartesioUI max temps

This commit is contained in:
Scott Lahteine 2023-06-05 16:30:03 -05:00
parent 81221882af
commit cee930d607

View file

@ -635,14 +635,14 @@
// Above this temperature the heater will be switched off.
// This can protect components from overheating, but NOT from shorts and failures.
// (Use MINTEMP for thermistor short/failure protection.)
#define HEATER_0_MAXTEMP 415
#define HEATER_1_MAXTEMP 415
#define HEATER_2_MAXTEMP 415
#define HEATER_3_MAXTEMP 415
#define HEATER_4_MAXTEMP 415
#define HEATER_5_MAXTEMP 415
#define HEATER_6_MAXTEMP 415
#define HEATER_7_MAXTEMP 415
#define HEATER_0_MAXTEMP 305
#define HEATER_1_MAXTEMP 305
#define HEATER_2_MAXTEMP 305
#define HEATER_3_MAXTEMP 305
#define HEATER_4_MAXTEMP 305
#define HEATER_5_MAXTEMP 305
#define HEATER_6_MAXTEMP 305
#define HEATER_7_MAXTEMP 305
#define BED_MAXTEMP 165
#define CHAMBER_MAXTEMP 60