📝 Misc. comment, order updates

This commit is contained in:
Scott Lahteine 2024-09-05 14:42:38 -05:00
parent ffe8fd3eb3
commit cbcae905b0
748 changed files with 9362 additions and 4500 deletions

View file

@ -1082,9 +1082,11 @@
#define HOME_AFTER_G34
#endif
//
// Add the G35 command to read bed corners to help adjust screws. Requires a bed probe.
//
/**
* Assisted Tramming
*
* Add the G35 command to measure bed corners and help adjust screws. Requires a bed probe.
*/
//#define ASSISTED_TRAMMING
#if ENABLED(ASSISTED_TRAMMING)
@ -1117,7 +1119,7 @@
// @section motion control
/**
* Fixed-time-based Motion Control -- EXPERIMENTAL
* Fixed-time-based Motion Control -- BETA FEATURE
* Enable/disable and set parameters with G-code M493.
* See ft_types.h for named values used by FTM options.
*/
@ -1181,7 +1183,7 @@
#endif
/**
* Input Shaping -- EXPERIMENTAL
* Input Shaping
*
* Zero Vibration (ZV) Input Shaping for X and/or Y movements.
*
@ -1495,8 +1497,17 @@
#define FEEDRATE_CHANGE_BEEP_FREQUENCY 50
#endif
/**
* Probe Offset Wizard
* Add a Probe Z Offset calibration option to the LCD menu.
* Use this helper to get a perfect 'M851 Z' probe offset.
* When launched this powerful wizard:
* - Measures the bed height at the configured position with the probe.
* - Moves the nozzle to the same position for a "paper" measurement.
* - The difference is used to set the probe Z offset.
*/
#if HAS_BED_PROBE && ANY(HAS_MARLINUI_MENU, HAS_TFT_LVGL_UI)
//#define PROBE_OFFSET_WIZARD // Add a Probe Z Offset calibration option to the LCD menu
//#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD)
/**
* Enable to init the Probe Z-Offset when starting the Wizard.
@ -1513,6 +1524,10 @@
#if HAS_MARLINUI_MENU
#if HAS_BED_PROBE
// Show Deploy / Stow Probe options in the Motion menu.
#define PROBE_DEPLOY_STOW_MENU
// Add calibration in the Probe Offsets menu to compensate for X-axis twist.
//#define X_AXIS_TWIST_COMPENSATION
#if ENABLED(X_AXIS_TWIST_COMPENSATION)
@ -1527,8 +1542,6 @@
#define XATC_Z_OFFSETS { 0, 0, 0 } // Z offsets for X axis sample points
#endif
// Show Deploy / Stow Probe options in the Motion menu.
#define PROBE_DEPLOY_STOW_MENU
#endif
// Include a page of printer information in the LCD Main Menu
@ -2569,7 +2582,7 @@
/**
* Minimum stepper driver pulse width (in ns)
* If undefined, these defaults (from Conditionals_adv.h) apply:
* If undefined, these defaults (from Conditionals-4-adv.h) apply:
* 100 : Minimum for TMC2xxx stepper drivers
* 500 : Minimum for LV8729
* 1000 : Minimum for A4988 and A5984 stepper drivers
@ -2583,7 +2596,7 @@
/**
* Maximum stepping rate (in Hz) the stepper driver allows
* If undefined, these defaults (from Conditionals_adv.h) apply:
* If undefined, these defaults (from Conditionals-4-adv.h) apply:
* 5000000 : Maximum for TMC2xxx stepper drivers
* 1000000 : Maximum for LV8729 stepper driver
* 500000 : Maximum for A4988 stepper driver
@ -2717,7 +2730,7 @@
/**
* Set the number of proportional font spaces required to fill up a typical character space.
* This can help to better align the output of commands like `G29 O` Mesh Output.
* This can help to better align the output of commands like 'G29 O' Mesh Output.
*
* For clients that use a fixed-width font (like OctoPrint), leave this set to 1.0.
* Otherwise, adjust according to your client and font.