PROBE_OFFSET_WIZARD_XY_POS

This commit is contained in:
Scott Lahteine 2020-11-17 20:28:02 -06:00
parent d3bd6e7795
commit a4daff8e81
196 changed files with 422 additions and 218 deletions

View file

@ -158,19 +158,33 @@
#endif #endif
/** /**
* Multi-Material Unit * Průša MK2 Single Nozzle Multi-Material Multiplexer, and variants.
* Set to one of these predefined models:
* *
* PRUSA_MMU1 : Průša MMU1 (The "multiplexer" version) * This device allows one stepper driver on a control board to drive
* PRUSA_MMU2 : Průša MMU2 * two to eight stepper motors, one at a time, in a manner suitable
* PRUSA_MMU2S : Průša MMU2S (Requires MK3S extruder with motion sensor, EXTRUDERS = 5) * for extruders.
* SMUFF_EMU_MMU2 : Technik Gegg SMUFF (Průša MMU2 emulation mode) *
* SMUFF_EMU_MMU2S : Technik Gegg SMUFF (Průša MMU2S emulation mode) * This option only allows the multiplexer to switch on tool-change.
* Additional options to configure custom E moves are pending.
*/
//#define MK2_MULTIPLEXER
#if ENABLED(MK2_MULTIPLEXER)
// Override the default DIO selector pins here, if needed.
// Some pins files may provide defaults for these pins.
//#define E_MUX0_PIN 40 // Always Required
//#define E_MUX1_PIN 42 // Needed for 3 to 8 inputs
//#define E_MUX2_PIN 44 // Needed for 5 to 8 inputs
#endif
/**
* Průša Multi-Material Unit v2
* *
* Requires NOZZLE_PARK_FEATURE to park print head in case MMU unit fails. * Requires NOZZLE_PARK_FEATURE to park print head in case MMU unit fails.
* See additional options in Configuration_adv.h. * Requires EXTRUDERS = 5
*
* For additional configuration see Configuration_adv.h
*/ */
//#define MMU_MODEL PRUSA_MMU2 //#define PRUSA_MMU2
// A dual extruder that uses a single stepper motor // A dual extruder that uses a single stepper motor
//#define SWITCHING_EXTRUDER //#define SWITCHING_EXTRUDER
@ -422,11 +436,11 @@
#define DUMMY_THERMISTOR_998_VALUE 25 #define DUMMY_THERMISTOR_998_VALUE 25
#define DUMMY_THERMISTOR_999_VALUE 100 #define DUMMY_THERMISTOR_999_VALUE 100
// Resistor values when using a MAX31865 (sensor -5) // Resistor values when using MAX31865 sensors (-5) on TEMP_SENSOR_0 / 1
// Sensor value is typically 100 (PT100) or 1000 (PT1000) //#define MAX31865_SENSOR_OHMS_0 100 // (Ω) Typically 100 or 1000 (PT100 or PT1000)
// Calibration value is typically 430 ohm for AdaFruit PT100 modules and 4300 ohm for AdaFruit PT1000 modules. //#define MAX31865_CALIBRATION_OHMS_0 430 // (Ω) Typically 430 for AdaFruit PT100; 4300 for AdaFruit PT1000
//#define MAX31865_SENSOR_OHMS 100 //#define MAX31865_SENSOR_OHMS_1 100
//#define MAX31865_CALIBRATION_OHMS 430 //#define MAX31865_CALIBRATION_OHMS_1 430
// Use temp sensor 1 as a redundant sensor with sensor 0. If the readings // Use temp sensor 1 as a redundant sensor with sensor 0. If the readings
// from the two sensors differ too much the print will be aborted. // from the two sensors differ too much the print will be aborted.
@ -2184,11 +2198,6 @@
//#define DGUS_LCD_UI_FYSETC //#define DGUS_LCD_UI_FYSETC
//#define DGUS_LCD_UI_HIPRECY //#define DGUS_LCD_UI_HIPRECY
//
// CR-6 OEM touch screen. A DWIN display with touch.
//
//#define DGUS_LCD_UI_CREALITY_TOUCH
// //
// Touch-screen LCD for Malyan M200/M300 printers // Touch-screen LCD for Malyan M200/M300 printers
// //
@ -2349,10 +2358,10 @@
#define TOUCH_SCREEN_CALIBRATION #define TOUCH_SCREEN_CALIBRATION
//#define XPT2046_X_CALIBRATION 12316 //#define TOUCH_CALIBRATION_X 12316
//#define XPT2046_Y_CALIBRATION -8981 //#define TOUCH_CALIBRATION_Y -8981
//#define XPT2046_X_OFFSET -43 //#define TOUCH_OFFSET_X -43
//#define XPT2046_Y_OFFSET 257 //#define TOUCH_OFFSET_Y 257
#if ENABLED(TFT_COLOR_UI) #if ENABLED(TFT_COLOR_UI)
//#define SINGLE_TOUCH_NAVIGATION //#define SINGLE_TOUCH_NAVIGATION

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3449,7 +3450,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1082,6 +1082,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3440,7 +3441,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3439,7 +3440,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3440,7 +3441,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1085,6 +1085,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3442,7 +3443,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
#define PROBE_OFFSET_WIZARD #define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1089,6 +1089,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3446,7 +3447,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3444,7 +3445,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3441,7 +3442,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1082,6 +1082,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3439,7 +3440,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1082,6 +1082,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3439,7 +3440,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1082,6 +1082,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3439,7 +3440,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1085,6 +1085,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3442,7 +3443,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1080,6 +1080,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3437,7 +3438,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3441,7 +3442,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3442,7 +3443,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1082,6 +1082,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3439,7 +3440,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1086,6 +1086,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

View file

@ -1081,6 +1081,7 @@
//#define PROBE_OFFSET_WIZARD //#define PROBE_OFFSET_WIZARD
#if ENABLED(PROBE_OFFSET_WIZARD) #if ENABLED(PROBE_OFFSET_WIZARD)
#define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra #define PROBE_OFFSET_START -4.0 // Estimated nozzle-to-probe Z offset, plus a little extra
//#define PROBE_OFFSET_WIZARD_XY_POS XY_CENTER // Set a convenient position to do the measurement
#endif #endif
#endif #endif
@ -3438,7 +3439,7 @@
#define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move #define GANTRY_CALIBRATION_FEEDRATE 500 // Feedrate for correction move
//#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction //#define GANTRY_CALIBRATION_TO_MIN // Enable to calibrate Z in the MIN direction
//#define GANTRY_CALIBRATION_SAFE_POSITION { X_CENTER, Y_CENTER } // Safe position for nozzle //#define GANTRY_CALIBRATION_SAFE_POSITION XY_CENTER // Safe position for nozzle
//#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM //#define GANTRY_CALIBRATION_XY_PARK_FEEDRATE 3000 // XY Park Feedrate - MMM
//#define GANTRY_CALIBRATION_COMMANDS_PRE "" //#define GANTRY_CALIBRATION_COMMANDS_PRE ""
#define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position #define GANTRY_CALIBRATION_COMMANDS_POST "G28" // G28 highly recommended to ensure an accurate position

Some files were not shown because too many files have changed in this diff Show more