📝 Update http links, misc. cleanup

This commit is contained in:
Scott Lahteine 2022-08-25 22:32:37 -05:00
parent 27e44456cc
commit 9cfbc08d74
32 changed files with 504 additions and 506 deletions

View file

@ -406,7 +406,7 @@
* Specify whether the power supply is active HIGH or active LOW.
*/
//#define PSU_CONTROL
#define PSU_NAME "MEAN WELL"
#define PSU_NAME "Mean Well"
#if ENABLED(PSU_CONTROL)
//#define MKS_PWC // Using the MKS PWC add-on
@ -809,8 +809,8 @@
#define PID_FUNCTIONAL_RANGE 10 // If the temperature difference between the target temperature and the actual temperature
// is more than PID_FUNCTIONAL_RANGE then the PID will be shut off and the heater will be set to min/max.
#define PID_EDIT_MENU // Add PID editing to the "Advanced Settings" menu. (~700 bytes of flash)
#define PID_AUTOTUNE_MENU // Add PID auto-tuning to the "Advanced Settings" menu. (~250 bytes of flash)
#define PID_EDIT_MENU // Add PID editing to the "Advanced Settings" menu. (~700 bytes of flash)
#define PID_AUTOTUNE_MENU // Add PID auto-tuning to the "Advanced Settings" menu. (~250 bytes of flash)
#endif
// @section safety
@ -1252,7 +1252,7 @@
* https://blog.kyneticcnc.com/2018/10/computing-junction-deviation-for-marlin.html
*/
#if DISABLED(CLASSIC_JERK)
#define JUNCTION_DEVIATION_MM 0.08 // (mm) Distance from real junction edge
#define JUNCTION_DEVIATION_MM 0.08 // (mm) Distance from real junction edge
#define JD_HANDLE_SMALL_SEGMENTS // Use curvature estimation instead of just the junction angle
// for small segments (< 1mm) with large junction angles (> 135°).
#endif
@ -1569,7 +1569,7 @@
* Example: `M851 Z-5` with a CLEARANCE of 4 => 9mm from bed to nozzle.
* But: `M851 Z+1` with a CLEARANCE of 2 => 2mm from bed to nozzle.
*/
#define Z_CLEARANCE_DEPLOY_PROBE 7 // Z Clearance for Deploy/Stow
#define Z_CLEARANCE_DEPLOY_PROBE 7 // Z Clearance for Deploy/Stow
#define Z_CLEARANCE_BETWEEN_PROBES 3 // Z Clearance between probe points
#define Z_CLEARANCE_MULTI_PROBE 3 // Z Clearance between multiple probes
//#define Z_AFTER_PROBING 5 // Z position after probing is done