#if ANY(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED, THERMAL_PROTECTION_CHAMBER, THERMAL_PROTECTION_COOLER)
|
||||
/**
|
||||
* Thermal Protection Variance Monitor - EXPERIMENTAL.
|
||||
* Kill the machine on a stuck temperature sensor. Disable if you get false positives.
|
||||
* Thermal Protection Variance Monitor - EXPERIMENTAL
|
||||
* Kill the machine on a stuck temperature sensor.
|
||||
*
|
||||
* This feature may cause some thermally-stable systems to halt. Be sure to test it throughly under
|
||||
* a variety of conditions. Disable if you get false positives.
|
||||
*
|
||||
* This feature ensures that temperature sensors are updating regularly. If sensors die or get "stuck",
|
||||
* or if Marlin stops reading them, temperatures will remain constant while heaters may still be powered!
|
||||
* This feature only monitors temperature changes so it should catch any issue, hardware or software.
|
||||
*
|
||||
* By default it uses the THERMAL_PROTECTION_*_PERIOD constants (above) for the time window, within which
|
||||
* at least one temperature change must occur, to indicate that sensor polling is working. If any monitored
|
||||
* heater's temperature remains totally constant (without even a fractional change) during this period, a
|
||||
* thermal malfunction error occurs and the printer is halted.
|
||||
*
|
||||
* A very stable heater might produce a false positive and halt the printer. In this case, try increasing
|
||||
* the corresponding THERMAL_PROTECTION_*_PERIOD constant a bit. Keep in mind that uncontrolled heating
|
||||
* shouldn't be allowed to persist for more than a minite or two.
|
||||
*
|
||||
* Be careful to distinguish false positives from real sensor issues before disabling this feature. If the
|
||||
* heater's temperature appears even slightly higher than expected after restarting, you may have a real
|
||||
* thermal malfunction. Check the temperature graph in your host for any unusual bumps.
|
||||
*/
|
||||
//#define THERMAL_PROTECTION_VARIANCE_MONITOR // Detect a sensor malfunction preventing temperature updates
|
||||
//#define THERMAL_PROTECTION_VARIANCE_MONITOR
|
||||
#if ENABLED(THERMAL_PROTECTION_VARIANCE_MONITOR)
|
||||
// Variance detection window to override the THERMAL_PROTECTION...PERIOD settings above.
|
||||
// Keep in mind that some heaters heat up faster than others.
|
||||
//#define THERMAL_PROTECTION_VARIANCE_MONITOR_PERIOD 30 // (s) Override all watch periods
|
||||
#endif
|
||||