Expose OVERSHOOT

MarlinFirmware/Marlin#21273
This commit is contained in:
Scott Lahteine 2021-03-06 22:41:21 -06:00
parent c734d0add8
commit 8206e02602
247 changed files with 2223 additions and 0 deletions

View file

@ -476,6 +476,15 @@
#define BED_MAXTEMP 150
#define CHAMBER_MAXTEMP 60
/**
* Thermal Overshoot
* During heatup (and printing) the temperature can often "overshoot" the target by many degrees
* (especially before PID tuning). Setting the target temperature too close to MAXTEMP guarantees
* a MAXTEMP shutdown! Use these values to forbid temperatures being set too close to MAXTEMP.
*/
#define HOTEND_OVERSHOOT 15 // (°C) Forbid temperatures over MAXTEMP - OVERSHOOT
#define BED_OVERSHOOT 10 // (°C) Forbid temperatures over MAXTEMP - OVERSHOOT
//===========================================================================
//============================= PID Settings ================================
//===========================================================================